Investigation of the effect of the gap at the zero-crossing point of PWMs creating the first level voltage in a multi-level inverter
Özet
The usage of multi-level inverters in converting direct current to alternating current is one of the most demanded and used methods. While creating multi-level voltage with inverters, the operating times of the switches that constitute the first step of the alternating voltage determine the gap of the step at the zero-crossing point. This situation can be preferred to create an extra level. Therefore, this article examines the effect of variation in operating times and frequencies of first-step PWMs on this zero-crossing point. First, the inverter structure providing load voltage is given in the study. Then, the transition of PWM run times is tried for different first-level voltages on the loads. The results obtained show the operation times of PWM at the transition point are quite effective on the load currents and voltages. © 2023 Kuwait University.
Anahtar Kelimeler
Tam Kayıt
| Alan | Değer | Dil |
|---|---|---|
| dc.contributor.author | Can, Erol | |
| dc.contributor.author | Sayan, Hasan Hüseyin | |
| dc.date.accessioned | 2026-10-18T20:27:00.866504674Z | |
| dc.date.available | 2026-10-18T20:27:00.866504674Z | |
| dc.date.issued | 2023 | |
| dc.description.abstract | The usage of multi-level inverters in converting direct current to alternating current is one of the most demanded and used methods. While creating multi-level voltage with inverters, the operating times of the switches that constitute the first step of the alternating voltage determine the gap of the step at the zero-crossing point. This situation can be preferred to create an extra level. Therefore, this article examines the effect of variation in operating times and frequencies of first-step PWMs on this zero-crossing point. First, the inverter structure providing load voltage is given in the study. Then, the transition of PWM run times is tried for different first-level voltages on the loads. The results obtained show the operation times of PWM at the transition point are quite effective on the load currents and voltages. © 2023 Kuwait University. | |
| dc.identifier.doi | 10.36909/jer.15941 | |
| dc.identifier.endpage | 168 | |
| dc.identifier.issn | 2307-1877 | |
| dc.identifier.issue | 3 | |
| dc.identifier.scopus | 2-s2.0-105022194992 | |
| dc.identifier.startpage | 157 | |
| dc.identifier.uri | https://rdlopen.rawdatalibrary.net/r/ebyu/12063 | |
| dc.identifier.volume | 11 | |
| dc.language.iso | en | |
| dc.publisher | Elsevier B.V. | |
| dc.relation.ispartof | Journal of Engineering Research (Kuwait) | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.subject | Different First-Level | |
| dc.subject | PWM Operating | |
| dc.subject | Zero-Point Grossing | |
| dc.title | Investigation of the effect of the gap at the zero-crossing point of PWMs creating the first level voltage in a multi-level inverter | |
| dc.type | Article | |
| dspace.entity.type | Publication | |
| rdl.citation.scopus | 1 | |
| rdl.oa.status | gold | |
| rdl.source.index | SCOPUS |