Purpose. Diagnose keratoconus by establishing an effective logistic regression model from the data obtained with a Scheimpflug-Placido cornea topographer. Methods. Topographical parameters of 125 eyes of 70 patients diagnosed with keratoconus by clinical or topographical findings were compared with 120 eyes of 63 patients who were defined as keratorefractive surgery candidates. The receiver operating character (ROC) curve analysis was performed to determine the diagnostic ability of the topographic parameters. The data set of parameters with an AUROC (area under the ROC curve) value greater than 0.9 was analyzed with logistic regression analysis (LRA) to determine the most predictive model that could diagnose keratoconus. A logit formula of the model was built, and the logit values of every eye in the study were calculated according to this formula. Then, an ROC analysis of the logit values was done. Results. Baiocchi Calossi Versaci front index (BCVf) had the highest AUROC value (0.976) in the study. The LRA model, which had the highest prediction ability, had 97.5% accuracy, 96.8% sensitivity, and 99.2% specificity. The most significant parameters were found to be BCVf (p=0.001), BCVb (Baiocchi Calossi Versaci back) (p=0.002), posterior rf (apical radius of the flattest meridian of the aspherotoric surface in 4.5 mm diameter of the cornea) (p=0.005), central corneal thickness (p=0.072), and minimum corneal thickness (p=0.494). Conclusions. The LRA model can distinguish keratoconus corneas from normal ones with high accuracy without the need for complex computer algorithms. © 2021 Emre Altinkurt et al.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/13098Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1155/2021/5528927Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorAltinkurt, Emre
dc.contributor.authorAvci, Ozkan
dc.contributor.authorMuftuoglu, Orkun
dc.contributor.authorUgurlu, Adem
dc.contributor.authorCebeci, Zafer
dc.contributor.authorOzbilen, Kemal Turgay
dc.date.accessioned2026-10-18T20:27:56.196602822Z
dc.date.available2026-10-18T20:27:56.196602822Z
dc.date.issued2021
dc.description.abstractPurpose. Diagnose keratoconus by establishing an effective logistic regression model from the data obtained with a Scheimpflug-Placido cornea topographer. Methods. Topographical parameters of 125 eyes of 70 patients diagnosed with keratoconus by clinical or topographical findings were compared with 120 eyes of 63 patients who were defined as keratorefractive surgery candidates. The receiver operating character (ROC) curve analysis was performed to determine the diagnostic ability of the topographic parameters. The data set of parameters with an AUROC (area under the ROC curve) value greater than 0.9 was analyzed with logistic regression analysis (LRA) to determine the most predictive model that could diagnose keratoconus. A logit formula of the model was built, and the logit values of every eye in the study were calculated according to this formula. Then, an ROC analysis of the logit values was done. Results. Baiocchi Calossi Versaci front index (BCVf) had the highest AUROC value (0.976) in the study. The LRA model, which had the highest prediction ability, had 97.5% accuracy, 96.8% sensitivity, and 99.2% specificity. The most significant parameters were found to be BCVf (p=0.001), BCVb (Baiocchi Calossi Versaci back) (p=0.002), posterior rf (apical radius of the flattest meridian of the aspherotoric surface in 4.5 mm diameter of the cornea) (p=0.005), central corneal thickness (p=0.072), and minimum corneal thickness (p=0.494). Conclusions. The LRA model can distinguish keratoconus corneas from normal ones with high accuracy without the need for complex computer algorithms. © 2021 Emre Altinkurt et al.
dc.identifier.doi10.1155/2021/5528927
dc.identifier.eissn2090-0058
dc.identifier.issn2090-004X
dc.identifier.pmcidPMC8154304
dc.identifier.pmid34113464
dc.identifier.scopus2-s2.0-85107231928
dc.identifier.startpage5528927
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/13098
dc.identifier.volume2021
dc.identifier.wosWOS:000668995900001
dc.language.isoen
dc.publisherHindawi Limited
dc.relation.ispartofJournal of Ophthalmology
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectadult
dc.subjectArticle
dc.subjectcomparative study
dc.subjectcontrolled study
dc.subjectcornea thickness
dc.subjectdiagnostic value
dc.subjectfemale
dc.subjecthuman
dc.subjectkeratoconus
dc.subjectlogistic regression analysis
dc.subjectmajor clinical study
dc.subjectmale
dc.subjectpredictive value
dc.subjectreceiver operating characteristic
dc.subjectsurface property
dc.titleLogistic Regression Model Using Scheimpflug-Placido Cornea Topographer Parameters to Diagnose Keratoconus
dc.typeArticle
dspace.entity.typePublication
rdl.citation.scopus7
rdl.citation.wos5
rdl.departmentErzincan University, Faculty of Medicine, Department of Ophthalmology, Fatih, Erzincan 24100, Turkey.
rdl.oa.statusgold
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.source.indexPUBMED
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)