Synthetic Bone Graft versus Autograft Obtained from the Spinous Process in Posterior Lumbar Interbody Fusion

ArticleAçık Erişim

Özet

Aim: To compare the clinical and radiological results of using synthetic bone graft versus autograft obtained from the spinous process in posterior lumbar interbody fusion. Material and Methods: This retrospective study included 102 patients with degenerative lumbar spondylolisthesis who underwent one-segment posterior lumbar interbody fusion (PLIF) followed by one-segment posterior transpedicular instrumentation. PLIF surgery was performed using a local solid bone graft obtained from the spinous process in group A and using a synthetic solid calcium hydroxyapatite block in group B. The Oswestry Disability Index (ODI), visual analogue scale (VAS) scores, degree of bone formation, intervertebral disc heights at the operation segment, wound infection, and instrumentation complications were compared between the 6-month and 5-year follow-ups. Results: In both groups, ODI and VAS scores significantly improved at the 6-month and 5-year follow-up. Bone formation at both 6 months and 5 years were higher in group A than that in group B, but without a significant difference when compared. Moreover, the difference in maintaining the intervertebral disc heights was not significant between the two groups. Surgical wound infection more commonly occurred in group B, but without significant difference between the two groups, and rod fractures were observed in two patients in group B; however, no metal breakage was observed in group A. Conclusion: Successful fusion of the intervertebral space and intervertebral height restoration can be achieved and maintained with an autograft from the patient’s spinous processes. © 2021. All Rights Reserved.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/13163Resmi atıflarda kullanılan kalıcı adres
Tam Kayıt
AlanDeğerDil
dc.contributor.authorCakir, Tayfun
dc.contributor.authorYolas, Coskun
dc.date.accessioned2026-10-18T20:28:00.280587672Z
dc.date.available2026-10-18T20:28:00.280587672Z
dc.date.issued2021
dc.description.abstractAim: To compare the clinical and radiological results of using synthetic bone graft versus autograft obtained from the spinous process in posterior lumbar interbody fusion. Material and Methods: This retrospective study included 102 patients with degenerative lumbar spondylolisthesis who underwent one-segment posterior lumbar interbody fusion (PLIF) followed by one-segment posterior transpedicular instrumentation. PLIF surgery was performed using a local solid bone graft obtained from the spinous process in group A and using a synthetic solid calcium hydroxyapatite block in group B. The Oswestry Disability Index (ODI), visual analogue scale (VAS) scores, degree of bone formation, intervertebral disc heights at the operation segment, wound infection, and instrumentation complications were compared between the 6-month and 5-year follow-ups. Results: In both groups, ODI and VAS scores significantly improved at the 6-month and 5-year follow-up. Bone formation at both 6 months and 5 years were higher in group A than that in group B, but without a significant difference when compared. Moreover, the difference in maintaining the intervertebral disc heights was not significant between the two groups. Surgical wound infection more commonly occurred in group B, but without significant difference between the two groups, and rod fractures were observed in two patients in group B; however, no metal breakage was observed in group A. Conclusion: Successful fusion of the intervertebral space and intervertebral height restoration can be achieved and maintained with an autograft from the patient’s spinous processes. © 2021. All Rights Reserved.
dc.identifier.doi10.5137/1019-5149.jtn.29765-20.2
dc.identifier.endpage205
dc.identifier.issn1019-5149
dc.identifier.issue2
dc.identifier.pmid33575994
dc.identifier.scopus2-s2.0-85103474322
dc.identifier.startpage199
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/13163
dc.identifier.volume31
dc.identifier.wosWOS:000631709500007
dc.language.isoen
dc.publisherTurkish Neurosurgical Society
dc.relation.ispartofTurkish Neurosurgery
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectAutograft
dc.subjectLumbar spondylolisthesis
dc.subjectPLIF
dc.subjectSpinous process
dc.subjectAdult
dc.subjectAged
dc.subjectAutografts
dc.subjectBiocompatible Materials
dc.subjectBone Transplantation
dc.subjectDurapatite
dc.subjectFemale
dc.subjectFollow-Up Studies
dc.subjectHumans
dc.subjectLumbar Vertebrae
dc.subjectMale
dc.subjectMiddle Aged
dc.subjectRetrospective Studies
dc.subjectSpinal Fusion
dc.subjectSpondylolisthesis
dc.subjectTransplantation, Autologous
dc.subjectTreatment Outcome
dc.subjectVertebral Body
dc.subjectbiomaterial
dc.subjecthydroxyapatite
dc.subjectautotransplantation
dc.subjectcomparative study
dc.subjectdiagnostic imaging
dc.subjectfollow up
dc.subjecthuman
dc.subjectlumbar vertebra
dc.titleSynthetic Bone Graft versus Autograft Obtained from the Spinous Process in Posterior Lumbar Interbody Fusion
dc.typeArticle
dspace.entity.typePublication
rdl.citation.scopus5
rdl.citation.wos3
rdl.departmentErzincan Binali Yildirim University, Faculty of Medicine, Department of Neurosurgery, Erzincan, Turkey.
rdl.oa.statusopen
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.source.indexPUBMED
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)