Facile Synthesis and Characterization of 5-[(3-Methylthiophene-2-yl-methyleneamino)]-2-mercaptobenzimidazole and Its Potentiometric Sensor Application in a Polyvinyl Chloride Membrane for the Determination of Copper(II)

ArticleAçık Erişim

Özet

A novel Schiff base designated as 5-[(3-methylthiophene-2-yl-methyleneamino)]-2-mercaptobenzimidazole was synthesized and characterized. A polyvinyl chloride-membrane potentiometric copper(II)-selective sensor was prepared by using the synthesized 5-[(3-methylthiophene-2-yl-methyleneamino)]-2-mercaptobenzimidazole compound. The prepared polyvinyl chloride-membrane copper(II)-selective sensor exhibited very good selectivity and sensitive potentiometric response towards copper(II) ions compared to a wide variety of other cations. The sensor had a fast response time of <5 s, and showed a linear Nerstian behavior to copper(II) ions over a wide concentration range from 1.0 × 10−5 to 1.0 × 10−1 mol L−1 with a slope of 29.2 ± 0.7 and correlation coefficient of 0.9998. The prepared polyvinyl chloride-membrane copper(II)-selective sensor was used for 14 weeks without any significant change in its potentiometric response. The potentiometric response of the developed sensor was highly repeatable. Additionally, the developed sensor was used as an indicator electrode for the potentiometric titration of copper(II) ion with ethylenediaminetetraacetic acid. The sensor was also successfully applied to the direct determination of copper(II) ions in tap water, river water, and dam water samples. © 2018, © 2018 Taylor & Francis.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/13697Resmi atıflarda kullanılan kalıcı adres
Tam Kayıt
AlanDeğerDil
dc.contributor.authorKardaş, Faruk
dc.date.accessioned2026-10-18T20:28:31.507157885Z
dc.date.available2026-10-18T20:28:31.507157885Z
dc.date.issued2019
dc.description.abstractA novel Schiff base designated as 5-[(3-methylthiophene-2-yl-methyleneamino)]-2-mercaptobenzimidazole was synthesized and characterized. A polyvinyl chloride-membrane potentiometric copper(II)-selective sensor was prepared by using the synthesized 5-[(3-methylthiophene-2-yl-methyleneamino)]-2-mercaptobenzimidazole compound. The prepared polyvinyl chloride-membrane copper(II)-selective sensor exhibited very good selectivity and sensitive potentiometric response towards copper(II) ions compared to a wide variety of other cations. The sensor had a fast response time of <5 s, and showed a linear Nerstian behavior to copper(II) ions over a wide concentration range from 1.0 × 10−5 to 1.0 × 10−1 mol L−1 with a slope of 29.2 ± 0.7 and correlation coefficient of 0.9998. The prepared polyvinyl chloride-membrane copper(II)-selective sensor was used for 14 weeks without any significant change in its potentiometric response. The potentiometric response of the developed sensor was highly repeatable. Additionally, the developed sensor was used as an indicator electrode for the potentiometric titration of copper(II) ion with ethylenediaminetetraacetic acid. The sensor was also successfully applied to the direct determination of copper(II) ions in tap water, river water, and dam water samples. © 2018, © 2018 Taylor & Francis.
dc.identifier.doi10.1080/00032719.2018.1543700
dc.identifier.eissn1532-236X
dc.identifier.endpage1431
dc.identifier.issn0003-2719
dc.identifier.issue9
dc.identifier.scopus2-s2.0-85058187278
dc.identifier.startpage1418
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/13697
dc.identifier.volume52
dc.identifier.wosWOS:000465611500004
dc.language.isoen
dc.publisherTaylor and Francis Inc.
dc.relation.ispartofAnalytical Letters
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectCopper(II) determination
dc.subjectpolyvinyl chloride-membrane sensor
dc.subjectpotentiometry
dc.subjectSchiff base
dc.titleFacile Synthesis and Characterization of 5-[(3-Methylthiophene-2-yl-methyleneamino)]-2-mercaptobenzimidazole and Its Potentiometric Sensor Application in a Polyvinyl Chloride Membrane for the Determination of Copper(II)
dc.typeArticle
dspace.entity.typePublication
rdl.citation.scopus3
rdl.citation.wos3
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)