Dependence of albedo factors on mean atomic number for 662 keV gamma photons

ArticleAçık Erişim

Özet

The albedo factors (number, energy and dose) of the samples with various mean atomic number have been investigated at a scattering angle of 180°. Fourteen different samples in the mean atomic number range 9.743 ≤ Z‾ ≤ 83.00 were obtained with bismuth and cellulose powders by using dilution technique. Thus, albedo factors have been investigated in a wide atomic number range. The samples were irritated by 662 keV gamma rays emitted from a137Cs radioactive source. The scattered γ -rays were counted by an HPGe detector with active area of 200 mm2. It has been observed that albedo factors decrease with increasing mean atomic number. Also, there is a high correlation between albedo factors and mean atomic numbers. © 2019 Elsevier Ltd

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/13881Resmi atıflarda kullanılan kalıcı adres
Tam Kayıt
AlanDeğerDil
dc.contributor.authorAkkuş, Tuba
dc.contributor.authorYılmaz, Demet
dc.date.accessioned2026-10-18T20:28:41.149038647Z
dc.date.available2026-10-18T20:28:41.149038647Z
dc.date.issued2019
dc.description.abstractThe albedo factors (number, energy and dose) of the samples with various mean atomic number have been investigated at a scattering angle of 180°. Fourteen different samples in the mean atomic number range 9.743 ≤ Z‾ ≤ 83.00 were obtained with bismuth and cellulose powders by using dilution technique. Thus, albedo factors have been investigated in a wide atomic number range. The samples were irritated by 662 keV gamma rays emitted from a137Cs radioactive source. The scattered γ -rays were counted by an HPGe detector with active area of 200 mm2. It has been observed that albedo factors decrease with increasing mean atomic number. Also, there is a high correlation between albedo factors and mean atomic numbers. © 2019 Elsevier Ltd
dc.identifier.doi10.1016/j.apradiso.2019.108870
dc.identifier.eissn1872-9800
dc.identifier.issn0969-8043
dc.identifier.pmid31454726
dc.identifier.scopus2-s2.0-85071090747
dc.identifier.startpage108870
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/13881
dc.identifier.volume154
dc.identifier.wosWOS:000498291900017
dc.language.isoen
dc.publisherElsevier Ltd
dc.relation.ispartofApplied Radiation and Isotopes
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectAlbedo factors
dc.subjectBackscattering
dc.subjectDilution
dc.subjectGamma rays
dc.subjectMean atomic number
dc.subjectGermanium Compounds
dc.subjectPhosphorus Compounds
dc.subjectRadioactivity
dc.subjectSun Light
dc.subjectSolar radiation
dc.subjectbismuth
dc.subjectcellulose
dc.subjectcesium 137
dc.subjectAtomic numbers
dc.subjectCellulose powder
dc.subjectDilution technique
dc.subjectGamma photons
dc.subjectHPGe detectors
dc.subjectRadioactive sources
dc.subjectScattering angles
dc.subjectalbedo
dc.subjectArticle
dc.subjectdosimetry
dc.subjectelectromagnetic radiation
dc.subjectgamma radiation
dc.subjectphoton
dc.subjectpriority journal
dc.subjectradiation dose
dc.subjectradiation energy
dc.subjectradiation scattering
dc.titleDependence of albedo factors on mean atomic number for 662 keV gamma photons
dc.typeArticle
dspace.entity.typePublication
rdl.citation.scopus8
rdl.citation.wos8
rdl.departmentDepartment of Physics, Faculty of Arts and Sciences, Erzincan Binali Yıldırım University, Erzincan, 24100, Turkey. Electronic address: takkus@erzincan.edu.tr.
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.source.indexPUBMED
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)