A highly selective and sensitive voltammetric sensor with molecularly imprinted polymer based silver@gold nanoparticles/ionic liquid modified glassy carbon electrode for determination of ceftizoxime
Özet
Ceftizoxime (CFX) is used to reduce the infection caused by both gram-negative and gram-positive bacteria. In this report, silver@gold nanoparticles (Ag@AuNPs) involved in 5-(5-bromo-2-hydroxybenzylidenamino)-2-mercaptobenzimidazole (ILs) was firstly synthesized. After that, CFX imprinted glassy carbon electrode (GCE) was prepared. The formation of the surfaces was characterized by scanning electron microscope (SEM), transmission electron microscope (TEM), electrochemical impedance spectroscopy (EIS) and x-ray photoelectron spectroscopy (XPS). CFX imprinted electrochemical surface was formed in the presence of 100.0 mM phenol containing 25.0 mM CFX as template. The linearity range and the detection limit (LOD) of the developed nanosensor were calculated as 1.0 × 10− 9 - 1.0 × 10− 11 M and 2.0 × 10− 12 M, respectively. © 2017 Elsevier B.V.
Anahtar Kelimeler
Tam Kayıt
| Alan | Değer | Dil |
|---|---|---|
| dc.contributor.author | Beytur, Murat | |
| dc.contributor.author | Kardaş, Faruk | |
| dc.contributor.author | Akyıldırım, Onur | |
| dc.contributor.author | Özkan, Abdullah | |
| dc.contributor.author | Bankoğlu, Bahar | |
| dc.contributor.author | Yüksek, Haydar | |
| dc.contributor.author | Yola, Mehmet Lütfi | |
| dc.contributor.author | Atar, Necip | |
| dc.date.accessioned | 2026-10-18T20:28:50.682191609Z | |
| dc.date.available | 2026-10-18T20:28:50.682191609Z | |
| dc.date.issued | 2018 | |
| dc.description.abstract | Ceftizoxime (CFX) is used to reduce the infection caused by both gram-negative and gram-positive bacteria. In this report, silver@gold nanoparticles (Ag@AuNPs) involved in 5-(5-bromo-2-hydroxybenzylidenamino)-2-mercaptobenzimidazole (ILs) was firstly synthesized. After that, CFX imprinted glassy carbon electrode (GCE) was prepared. The formation of the surfaces was characterized by scanning electron microscope (SEM), transmission electron microscope (TEM), electrochemical impedance spectroscopy (EIS) and x-ray photoelectron spectroscopy (XPS). CFX imprinted electrochemical surface was formed in the presence of 100.0 mM phenol containing 25.0 mM CFX as template. The linearity range and the detection limit (LOD) of the developed nanosensor were calculated as 1.0 × 10− 9 - 1.0 × 10− 11 M and 2.0 × 10− 12 M, respectively. © 2017 Elsevier B.V. | |
| dc.identifier.doi | 10.1016/j.molliq.2017.12.060 | |
| dc.identifier.eissn | 1873-3166 | |
| dc.identifier.endpage | 217 | |
| dc.identifier.issn | 0167-7322 | |
| dc.identifier.scopus | 2-s2.0-85038847065 | |
| dc.identifier.startpage | 212 | |
| dc.identifier.uri | https://rdlopen.rawdatalibrary.net/r/ebyu/14054 | |
| dc.identifier.volume | 251 | |
| dc.identifier.wos | WOS:000425564300025 | |
| dc.language.iso | en | |
| dc.publisher | Elsevier B.V. | |
| dc.relation.ispartof | Journal of Molecular Liquids | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.subject | Ceftizoxime | |
| dc.subject | Characterization | |
| dc.subject | Core@shell nanoparticles | |
| dc.subject | Molecularly imprinted polymer | |
| dc.subject | Bacteria | |
| dc.subject | Carbon | |
| dc.subject | Core shell nanoparticles | |
| dc.subject | Electrochemical impedance spectroscopy | |
| dc.subject | Fiber optic sensors | |
| dc.subject | Glass | |
| dc.subject | Glass membrane electrodes | |
| dc.subject | Gold nanoparticles | |
| dc.subject | Metal nanoparticles | |
| dc.subject | Scanning electron microscopy | |
| dc.subject | Synthesis (chemical) | |
| dc.subject | Transmission electron microscopy | |
| dc.subject | X ray photoelectron spectroscopy | |
| dc.subject | Electrochemical surfaces | |
| dc.subject | Glassy carbon electrodes | |
| dc.subject | Gram-positive bacterium | |
| dc.subject | Mercaptobenzimidazole | |
| dc.subject | Modified glassy carbon electrode | |
| dc.subject | Voltammetric sensor | |
| dc.subject | Silver nanoparticles | |
| dc.title | A highly selective and sensitive voltammetric sensor with molecularly imprinted polymer based silver@gold nanoparticles/ionic liquid modified glassy carbon electrode for determination of ceftizoxime | |
| dc.type | Article | |
| dspace.entity.type | Publication | |
| rdl.citation.scopus | 110 | |
| rdl.citation.wos | 106 | |
| rdl.source.index | SCOPUS | |
| rdl.source.index | WOS | |
| rdl.wos.index | Science Citation Index Expanded (SCI-EXPANDED) |
