Electrochemical Determination of Copper(II) in Water Samples Using a Novel Ion-Selective Electrode Based on a Graphite Oxide–Imprinted Polymer Composite

ArticleAçık Erişim

Özet

A novel copper(II)-selective electrode based on graphite oxide/imprinted polymer composite was developed for the electrochemical monitoring of copper(II) (Cu2+) ions. The electrode exhibited highly selective potentiometric response to Cu2+ with respect to common alkaline, alkaline earth and heavy metal cations. The composite composition studies indicated that the most suitable composite composition performing the most promising potentiometric properties was 20.0% ionophore (Cu2+-ion imprinted polymer), 10.0% paraffin oil, 5.0% multiwalled carbon nanotubes, and 65.0% graphite oxide. The fabricated electrode exhibited a linear response to Cu2+ over the concentration range of 1.0 × 10− 6–1.0 × 10− 1 M (correlation coefficient of 0.9998) with a sensitivity of 26.1 ± 0.9 mV decade− 1. The detection limit of the fabricated electrode was determined to be 4.0 × 10− 7 M. The electrode worked well in the pH range of 4.0–8.0. The electrode had stable, reversible and fast potentiometric response (3 s). In addition, the electrode had a lifetime of more than 1 year. The analytical applications of the proposed electrode were performed using as an indicator electrode for the potentiometric titration of Cu2+ with ethylene diamine tetraacetic acid solution and for the determination of Cu2+ of spiked river, dam, and tap water samples. The obtained results for potentiometric titration and water samples were satisfactory. © 2017 Taylor & Francis.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/14148Resmi atıflarda kullanılan kalıcı adres
Tam Kayıt
AlanDeğerDil
dc.contributor.authorTopcu, Cihan
dc.contributor.authorLacin, Gamze
dc.contributor.authorYilmaz, Vedat
dc.contributor.authorColdur, Fatih
dc.contributor.authorCaglar, Bulent
dc.contributor.authorCubuk, Osman
dc.contributor.authorIsildak, Ibrahim
dc.date.accessioned2026-10-18T20:28:56.079538083Z
dc.date.available2026-10-18T20:28:56.079538083Z
dc.date.issued2018
dc.description.abstractA novel copper(II)-selective electrode based on graphite oxide/imprinted polymer composite was developed for the electrochemical monitoring of copper(II) (Cu2+) ions. The electrode exhibited highly selective potentiometric response to Cu2+ with respect to common alkaline, alkaline earth and heavy metal cations. The composite composition studies indicated that the most suitable composite composition performing the most promising potentiometric properties was 20.0% ionophore (Cu2+-ion imprinted polymer), 10.0% paraffin oil, 5.0% multiwalled carbon nanotubes, and 65.0% graphite oxide. The fabricated electrode exhibited a linear response to Cu2+ over the concentration range of 1.0 × 10− 6–1.0 × 10− 1 M (correlation coefficient of 0.9998) with a sensitivity of 26.1 ± 0.9 mV decade− 1. The detection limit of the fabricated electrode was determined to be 4.0 × 10− 7 M. The electrode worked well in the pH range of 4.0–8.0. The electrode had stable, reversible and fast potentiometric response (3 s). In addition, the electrode had a lifetime of more than 1 year. The analytical applications of the proposed electrode were performed using as an indicator electrode for the potentiometric titration of Cu2+ with ethylene diamine tetraacetic acid solution and for the determination of Cu2+ of spiked river, dam, and tap water samples. The obtained results for potentiometric titration and water samples were satisfactory. © 2017 Taylor & Francis.
dc.identifier.doi10.1080/00032719.2017.1395035
dc.identifier.eissn1532-236X
dc.identifier.endpage1910
dc.identifier.issn0003-2719
dc.identifier.issue12
dc.identifier.scopus2-s2.0-85044445703
dc.identifier.startpage1890
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/14148
dc.identifier.volume51
dc.identifier.wosWOS:000430986500006
dc.language.isoen
dc.publisherTaylor and Francis Inc.
dc.relation.ispartofAnalytical Letters
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectCopper(II) determination
dc.subjectcopper(II)-selective electrode
dc.subjection-imprinted polymer
dc.subjectpotentiometry
dc.subjectwater analysis
dc.titleElectrochemical Determination of Copper(II) in Water Samples Using a Novel Ion-Selective Electrode Based on a Graphite Oxide–Imprinted Polymer Composite
dc.typeArticle
dspace.entity.typePublication
rdl.citation.scopus75
rdl.citation.wos65
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)