Comparison of conventional methods and automated systems for determining antibiotic susceptibility of bacteria isolated from urine culture

ArticleAçık Erişim

Özet

Objective: The aim of our study was to compare the results obtained from different methods, which are used to determine the susceptibility to antimicrobials, and to determine the agreement between them. Materials and Methods: A total of 397 strains consisting of 329 gram negative and 68 gram positive bacteria that were isolated from urine samples and identification and antibiogram of which were performed by automated systems, were included in the study. The results obtained from broth microdilution, E test, VITEK and disk diffusion were compared. Results: Our antimicrobial susceptibility test results in gram negative bacteria showed a categorical agreement of 93.3% with a very major error rate of 1.5 in disk diffusion test, while a categorical agreement of 90% with a very major error rate of 2.2% in Vitek 2 test. The agreement for E test was 95.3% with a very major error rate of 1.1. In the antimicrobial susceptibility test of gram positive bacteria, the rate of agreement for disk diffusion, E test and Vitek 2 was 97.2%, 98.4% and 95.4% respectively. Very major error rate was found % 1.5 ve % 2.6 in disk diffusion and Vitek 2, respectively, while no very major error was found in E test. Conclusions: In conclusion, our data suggest that disk diffusion test, Vitek 2 system and E test test are accurate and acceptable for antibiotic susceptibility tests of gram positive bacteria. The agreement rate of BMD and E test methods was found above 90% for all antibiotics, and it was reached a conclusion that the susceptibility results of gram negative bacteria for ceftriaxone and nitrofurantoin obtained from VITEK; the susceptibility results of disk diffusion test for ceftriaxone and ciprofloxacin should be confirmed by a more reliable method. © 2019, Ibn Sina Trust. All rights reserved.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/14382Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.3329/bjms.v18i3.41620Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorKoçoğlu, Mücahide Esra
dc.contributor.authorDavarci, İsmail
dc.contributor.authorGüney, Rabia
dc.contributor.authorTaşçilar, Melike
dc.contributor.authorZengi̇n, Ferhat
dc.contributor.authorSamsati, Mustafa
dc.date.accessioned2026-10-18T20:29:10.628630826Z
dc.date.available2026-10-18T20:29:10.628630826Z
dc.date.issued2019
dc.description.abstractObjective: The aim of our study was to compare the results obtained from different methods, which are used to determine the susceptibility to antimicrobials, and to determine the agreement between them. Materials and Methods: A total of 397 strains consisting of 329 gram negative and 68 gram positive bacteria that were isolated from urine samples and identification and antibiogram of which were performed by automated systems, were included in the study. The results obtained from broth microdilution, E test, VITEK and disk diffusion were compared. Results: Our antimicrobial susceptibility test results in gram negative bacteria showed a categorical agreement of 93.3% with a very major error rate of 1.5 in disk diffusion test, while a categorical agreement of 90% with a very major error rate of 2.2% in Vitek 2 test. The agreement for E test was 95.3% with a very major error rate of 1.1. In the antimicrobial susceptibility test of gram positive bacteria, the rate of agreement for disk diffusion, E test and Vitek 2 was 97.2%, 98.4% and 95.4% respectively. Very major error rate was found % 1.5 ve % 2.6 in disk diffusion and Vitek 2, respectively, while no very major error was found in E test. Conclusions: In conclusion, our data suggest that disk diffusion test, Vitek 2 system and E test test are accurate and acceptable for antibiotic susceptibility tests of gram positive bacteria. The agreement rate of BMD and E test methods was found above 90% for all antibiotics, and it was reached a conclusion that the susceptibility results of gram negative bacteria for ceftriaxone and nitrofurantoin obtained from VITEK; the susceptibility results of disk diffusion test for ceftriaxone and ciprofloxacin should be confirmed by a more reliable method. © 2019, Ibn Sina Trust. All rights reserved.
dc.description.sponsorshipAlthough our overall agreement rates were over 90% and total error rates were below 10% considering overall agreement rates, the agreement rate of Vitek 2 results was found to be relatively lower than the agreement rates of other two methods. Although we did not evaluate the performance of the tests in this type of strains due to the low rate of specific resistant strains in our study, we are of the opinion that the results of gram negative bacteria for ceftriaxone and nitrofurantoin obtained from automated systems; and the results of ceftriaxone and ciprofloxacin obtained by disk diffusion test should be confirmed by a more reliable method. Acknowledgements We would like to thank Prof. Handan ANKARALI for her contributions to the statistical analyses of our study. We thank the Istanbul Medeniyet University, Scientific Research Projects Coordination Unit for its support in the realization of the project (T-GAP-2017-969). Conflicts of interest None declared Author’s contribution: Data gathering and idea owner of this study: KOÇOĞLU ME, DAVARCI I, GÜNEY R, TAŞÇILAR M, Studydesign:KOÇOĞLUME, DAVARCI I,GÜNEY R, TAŞÇILAR M, ZENGİN F, SAMASTI M Data gathering: KOÇOĞLU ME, DAVARCI I, ZENGİN F, SAMASTI M Writing and submitting manuscript: KOÇOĞLU ME, DAVARCI I, GÜNEY R, TAŞÇILAR M, Editing and approval of final draft: All authors
dc.identifier.doi10.3329/bjms.v18i3.41620
dc.identifier.eissn2076-0299
dc.identifier.endpage526
dc.identifier.issn2223-4721
dc.identifier.issue3
dc.identifier.scopus2-s2.0-85067977337
dc.identifier.startpage519
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/14382
dc.identifier.volume18
dc.identifier.wosWOS:000469991300011
dc.language.isoen
dc.publisherIbn Sina Trust
dc.relation.ispartofBangladesh Journal of Medical Science
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectBacterial Susceptibility Tests
dc.subjectDisk Diffusion Antimicrobial Tests
dc.subjectEnterobacteriaceae
dc.subjectGram-Positive Bacteria
dc.subjectampicillin
dc.subjectceftriaxone
dc.subjectcefuroxime
dc.subjectciprofloxacin
dc.subjectertapenem
dc.subjectgentamicin
dc.subjectnitrofurantoin
dc.subjectvancomycin
dc.subjectagar diffusion
dc.subjectantibiotic resistance
dc.subjectantibiotic sensitivity
dc.subjectArticle
dc.subjectbacterium isolation
dc.subjectbroth dilution
dc.subjectcomparative study
dc.subjectcontrolled study
dc.subjectcost effectiveness analysis
dc.subjectdiffusion
dc.subjectdisk diffusion
dc.subjectEnterococcus faecalis
dc.subjectepsilometer test
dc.subjectEscherichia coli
dc.subjectgradient diffusion
dc.subjectGram positive bacterium
dc.subjectKlebsiella
dc.subjectmatrix assisted laser desorption ionization time of flight mass spectrometry
dc.titleComparison of conventional methods and automated systems for determining antibiotic susceptibility of bacteria isolated from urine culture
dc.typeArticle
dspace.entity.typePublication
rdl.citation.scopus7
rdl.citation.wos6
rdl.oa.statusgold
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexEmerging Sources Citation Index (ESCI)