Energy and exergy analyses of a solar assisted combined power and cooling cycle

Conference ObjectAçık Erişim

Özet

In this study, a thermodynamic analysis of a solar assisted Rankine-Goswami integrated cycle is carried out for a range from 230 to 240 MW sizes. To illustrate the performance characteristics of these integrated cycle, an exergy analysis is conducted to pinpoint the losses due to internal and external irreversibilities of each component. In addition, the effect of design parameter such as condenser pressure on the performance of the integrated cycle is examined. The results shows that the variation of condenser pressure from 4 kPa to 24 kPa greatly reduces the exergy efficiency of the system. Moreover, it is found the exergy efficiency of standard solar assisted Rankine cycle case is 42.8% whereas the exergy efficiency of solar Rankine-Goswami multigeneration system is 47.03%. © 2016 IEEE.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/15067Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1109/icrera.2016.7884511Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorGanjehsarabi, Hadi
dc.contributor.authorAsker, Mustafa
dc.contributor.authorSeyhan, Aslihan Kurnuc
dc.date.accessioned2026-10-18T20:29:51.557403527Z
dc.date.available2026-10-18T20:29:51.557403527Z
dc.date.issued2016
dc.description.abstractIn this study, a thermodynamic analysis of a solar assisted Rankine-Goswami integrated cycle is carried out for a range from 230 to 240 MW sizes. To illustrate the performance characteristics of these integrated cycle, an exergy analysis is conducted to pinpoint the losses due to internal and external irreversibilities of each component. In addition, the effect of design parameter such as condenser pressure on the performance of the integrated cycle is examined. The results shows that the variation of condenser pressure from 4 kPa to 24 kPa greatly reduces the exergy efficiency of the system. Moreover, it is found the exergy efficiency of standard solar assisted Rankine cycle case is 42.8% whereas the exergy efficiency of solar Rankine-Goswami multigeneration system is 47.03%. © 2016 IEEE.
dc.identifier.doi10.1109/icrera.2016.7884511
dc.identifier.endpage1145
dc.identifier.isbn978-150903388-1
dc.identifier.scopus2-s2.0-85017201744
dc.identifier.startpage1141
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/15067
dc.language.isoen
dc.publisherInstitute of Electrical and Electronics Engineers Inc.
dc.relation.ispartof2016 IEEE International Conference on Renewable Energy Research and Applications, ICRERA 2016
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectEnergy resource utilization
dc.subjectGoswami cycle
dc.subjectMultigeneration integrated systems
dc.subjectEnergy resources
dc.subjectThermoanalysis
dc.subjectEnergy and exergy analysis
dc.subjectExergy efficiencies
dc.subjectIntegrated systems
dc.subjectInternal and external irreversibilities
dc.subjectPerformance characteristics
dc.subjectResource utilizations
dc.subjectThermo dynamic analysis
dc.subjectExergy
dc.titleEnergy and exergy analyses of a solar assisted combined power and cooling cycle
dc.typeConference Object
dspace.entity.typePublication
rdl.citation.scopus12
rdl.source.indexSCOPUS