Tests of CMS hadron forward calorimeter upgrade readout box prototype
ArticleAçık Erişim
Özet
A readout box prototype for the CMS Hadron Forward calorimeter upgrade was built and tested in the CERN H2 beamline. The prototype was designed to enable simultaneous tests of different readout options for the four anode upgrade PMTs, new front-end electronics design and new cabling. The response of the PMTs with different readout options was uniform and the background response was minimal. Multi-channel readout options further enhanced the background elimination. Passing all the electronic, mechanical and physics tests, the readout box proved to be capable of providing the forward hadron calorimeter operational requirements in the upgrade era. © 2012 IOP Publishing Ltd and Sissa Medialab srl.
Anahtar Kelimeler
CalorimetersCherenkov and transition radiationCherenkov detectorsPhoton detectors for UV visible and IR photons (vacuum)Cerenkov countersCosmic ray detectorsParticle beamsPhotonsReadout systemsBackground responseBeam-linesElectronic designFront endMulti channelPhoton detectorPhoton detector for UV visible and IR photon (vacuum)UV-visibleHadrons
RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/15736Resmi atıflarda kullanılan kalıcı adresTam Kayıt
| Alan | Değer | Dil |
|---|---|---|
| dc.contributor.author | Chatrchyan, S. | |
| dc.contributor.author | Khachatryan, V. | |
| dc.contributor.author | Sirunyan, A.M. | |
| dc.contributor.author | Tumasyan, A. | |
| dc.contributor.author | Mossolov, V. | |
| dc.contributor.author | Shumeiko, N. | |
| dc.contributor.author | Cornelis, T. | |
| dc.contributor.author | Ochesanu, S. | |
| dc.contributor.author | Roland, B. | |
| dc.contributor.author | Staykova, Z. | |
| dc.contributor.author | Van Haevermaet, H. | |
| dc.contributor.author | Van Mechelen, P. | |
| dc.contributor.author | Van Spilbeeck, A. | |
| dc.contributor.author | G.a., Alves | |
| dc.contributor.author | Junior, M.C.M. | |
| dc.contributor.author | Martins, T. | |
| dc.contributor.author | Pol, M.E. | |
| dc.contributor.author | Vaz, M. | |
| dc.contributor.author | Alda Junior, W.L. | |
| dc.contributor.author | Carvalho, W. | |
| dc.contributor.author | Chinellato, J. | |
| dc.contributor.author | De Oliveira Martins, C. | |
| dc.contributor.author | Matos Figueiredo, D. | |
| dc.contributor.author | Manganote, E. | |
| dc.contributor.author | Molina, J. | |
| dc.contributor.author | Mundim, L. | |
| dc.contributor.author | Nogima, H. | |
| dc.contributor.author | Prado Da Silva, W.L. | |
| dc.contributor.author | Santoro, A. | |
| dc.contributor.author | Zachi, A. | |
| dc.contributor.author | Finger, M. | |
| dc.contributor.author | Tsamalaidze, Z. | |
| dc.contributor.author | Borras, K. | |
| dc.contributor.author | Gunnelini, P. | |
| dc.contributor.author | Jung, H. | |
| dc.contributor.author | Knutsson, A. | |
| dc.contributor.author | Lutz, B. | |
| dc.contributor.author | Ribeiro Cipriano, P.M. | |
| dc.contributor.author | Sen, N. | |
| dc.contributor.author | Baus, C. | |
| dc.contributor.author | Katkov, I. | |
| dc.contributor.author | Ulrich, R. | |
| dc.contributor.author | Wohrmann, H. | |
| dc.contributor.author | Panagiotou, A. | |
| dc.contributor.author | Bencze, G. | |
| dc.contributor.author | Horvath, D. | |
| dc.contributor.author | Beri, S.B. | |
| dc.contributor.author | Gupta, R. | |
| dc.contributor.author | Kaur, M. | |
| dc.contributor.author | Mittal, M. | |
| dc.date.accessioned | 2026-10-18T20:30:35.039369601Z | |
| dc.date.available | 2026-10-18T20:30:35.039369601Z | |
| dc.date.issued | 2012 | |
| dc.description.abstract | A readout box prototype for the CMS Hadron Forward calorimeter upgrade was built and tested in the CERN H2 beamline. The prototype was designed to enable simultaneous tests of different readout options for the four anode upgrade PMTs, new front-end electronics design and new cabling. The response of the PMTs with different readout options was uniform and the background response was minimal. Multi-channel readout options further enhanced the background elimination. Passing all the electronic, mechanical and physics tests, the readout box proved to be capable of providing the forward hadron calorimeter operational requirements in the upgrade era. © 2012 IOP Publishing Ltd and Sissa Medialab srl. | |
| dc.description.sponsorship | Science and Technology Facilities Council, STFC, (CMS); Science and Technology Facilities Council, STFC | |
| dc.identifier.doi | 10.1088/1748-0221/7/10/p10015 | |
| dc.identifier.issn | 1748-0221 | |
| dc.identifier.issue | 10 | |
| dc.identifier.scopus | 2-s2.0-84868520808 | |
| dc.identifier.startpage | P10015 | |
| dc.identifier.uri | https://rdlopen.rawdatalibrary.net/r/ebyu/15736 | |
| dc.identifier.volume | 7 | |
| dc.language.iso | en | |
| dc.publisher | Institute of Physics | |
| dc.relation.ispartof | Journal of Instrumentation | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.subject | Calorimeters | |
| dc.subject | Cherenkov and transition radiation | |
| dc.subject | Cherenkov detectors | |
| dc.subject | Photon detectors for UV visible and IR photons (vacuum) | |
| dc.subject | Cerenkov counters | |
| dc.subject | Cosmic ray detectors | |
| dc.subject | Particle beams | |
| dc.subject | Photons | |
| dc.subject | Readout systems | |
| dc.subject | Background response | |
| dc.subject | Beam-lines | |
| dc.subject | Electronic design | |
| dc.subject | Front end | |
| dc.subject | Multi channel | |
| dc.subject | Photon detector | |
| dc.subject | Photon detector for UV visible and IR photon (vacuum) | |
| dc.subject | UV-visible | |
| dc.subject | Hadrons | |
| dc.title | Tests of CMS hadron forward calorimeter upgrade readout box prototype | |
| dc.type | Article | |
| dspace.entity.type | Publication | |
| rdl.citation.scopus | 5 | |
| rdl.oa.status | green | |
| rdl.source.index | SCOPUS |
