A Flow-Injection Potentiometric System for Selective and Sensitive Determination of Serum Lithium Level
ArticleAçık Erişim
Özet
A potentiometric flow injection system was adopted by using a Li+-selective electrode with improved selectivity for sensitive and selective determination of Li+ in human serum spiked samples. For the optimization of the offered flow injection system, multivariate method was utilized. Potentiometric characteristics of the system were investigated (linear range: 5.0×10-5-1.0×10-1molL-1, slope: 56.93mV per decade, detection limit: 3.4×10-5molL-1, sampling-rate: 40 injections per hour). The detection of Li+ in real serum samples was achieved. The obtained results for the spiked serum samples were in good agreement with IC results at 95% confidence level. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Anahtar Kelimeler
RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/15861Resmi atıflarda kullanılan kalıcı adresTam Kayıt
| Alan | Değer | Dil |
|---|---|---|
| dc.contributor.author | Coldur, Fatih | |
| dc.contributor.author | Andac, Muberra | |
| dc.date.accessioned | 2026-10-18T20:30:42.577318294Z | |
| dc.date.available | 2026-10-18T20:30:42.577318294Z | |
| dc.date.issued | 2013 | |
| dc.description.abstract | A potentiometric flow injection system was adopted by using a Li+-selective electrode with improved selectivity for sensitive and selective determination of Li+ in human serum spiked samples. For the optimization of the offered flow injection system, multivariate method was utilized. Potentiometric characteristics of the system were investigated (linear range: 5.0×10-5-1.0×10-1molL-1, slope: 56.93mV per decade, detection limit: 3.4×10-5molL-1, sampling-rate: 40 injections per hour). The detection of Li+ in real serum samples was achieved. The obtained results for the spiked serum samples were in good agreement with IC results at 95% confidence level. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim. | |
| dc.description.sponsorship | The authors gratefully acknowledge the financial support from The Scientific and Technological Research Council of Turkey (TUBITAK) (Project No: 107T-356) and Ondokuz Mayis University (Project No: OMU-BAP F-448). | |
| dc.identifier.doi | 10.1002/elan.201200466 | |
| dc.identifier.eissn | 1521-4109 | |
| dc.identifier.endpage | 740 | |
| dc.identifier.issn | 1040-0397 | |
| dc.identifier.issue | 3 | |
| dc.identifier.scopus | 2-s2.0-84874961982 | |
| dc.identifier.startpage | 732 | |
| dc.identifier.uri | https://rdlopen.rawdatalibrary.net/r/ebyu/15861 | |
| dc.identifier.volume | 25 | |
| dc.identifier.wos | WOS:000316213900021 | |
| dc.language.iso | en | |
| dc.publisher | Wiley-VCH Verlag | |
| dc.relation.ispartof | Electroanalysis | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.subject | Experimental design | |
| dc.subject | Flow injection analysis | |
| dc.subject | Lithium determination | |
| dc.subject | Multivariate optimization | |
| dc.subject | Serum analysis | |
| dc.subject | Body fluids | |
| dc.subject | Multivariant analysis | |
| dc.subject | Potentiometers (electric measuring instruments) | |
| dc.subject | Flow injection | |
| dc.subject | Flow-injection system | |
| dc.subject | Li + | |
| dc.subject | Potentiometric flows | |
| dc.subject | Potentiometrics | |
| dc.subject | Serum samples | |
| dc.subject | Lithium | |
| dc.title | A Flow-Injection Potentiometric System for Selective and Sensitive Determination of Serum Lithium Level | |
| dc.type | Article | |
| dspace.entity.type | Publication | |
| rdl.citation.scopus | 23 | |
| rdl.citation.wos | 22 | |
| rdl.source.index | SCOPUS | |
| rdl.source.index | WOS | |
| rdl.wos.index | Science Citation Index Expanded (SCI-EXPANDED) |
