Importance of the Hounsfield Unit Value Measured by Computed Tomography in the Differentiation of Hydronephrosis and Pyonephrosis

ArticleAçık Erişim

Özet

Objectives To evaluate the efficacy of the non-contrast-enhanced computed tomography (NCECT) renal pelvis Hounsfield unit (HU) values in differentiating between the hydronephrosis and pyonephrosis in dilated urinary systems. Materials and methods Patients who underwent percutaneous nephrostomy (PN) due to urinary system obstruction in the last three years were retrospectively evaluated. Pyonephrosis and hydronephrosis groups were differentiated according to the clarity of percutaneous needle aspiration. The patients' renal pelvic anteroposterior (AP) diameter, renal pelvic area, and mean HU values were measured on NCECT and compared between two groups. Results PN was performed on a total of 523 patients. The study included 159 patients and 214 renal units. Hydronephrosis was detected in 176 renal units and pyonephrosis in 38 renal units. No statistically significant difference was observed between the measured AP diameter and renal pelvic area in the two groups (28.45 +/- 10.1 mm vs. 31.13 +/- 14.4 mm, p = 0.36 and 658.51 +/- 433.1 mm2 vs. 755.14 +/- 470.6 mm2, p = 0.22, respectively). The mean HU value of the pyonephrosis group was significantly higher (2.30 +/- 5.02 vs. 10.97 +/- 6.68, p < 0.001). At the cut-off value of 8.46, HU had a sensitivity of 68.4% and specificity of 92.6% in the diagnosis of pyonephrosis. Conclusions It is possible to determine differential diagnosis between pyonephrosis and hydronephrosis easily and without additional cost by performing dilated renal pelvis HU measurements on NCECT.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/16521Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.7759/cureus.11675Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorErdogan, Abdullah
dc.contributor.authorSambel, Murat
dc.contributor.authorCaglayan, Volkan
dc.contributor.authorAvci, Sinan
dc.date.accessioned2026-10-18T20:36:24.117488893Z
dc.date.available2026-10-18T20:36:24.117488893Z
dc.date.issued2020
dc.description.abstractObjectives To evaluate the efficacy of the non-contrast-enhanced computed tomography (NCECT) renal pelvis Hounsfield unit (HU) values in differentiating between the hydronephrosis and pyonephrosis in dilated urinary systems. Materials and methods Patients who underwent percutaneous nephrostomy (PN) due to urinary system obstruction in the last three years were retrospectively evaluated. Pyonephrosis and hydronephrosis groups were differentiated according to the clarity of percutaneous needle aspiration. The patients' renal pelvic anteroposterior (AP) diameter, renal pelvic area, and mean HU values were measured on NCECT and compared between two groups. Results PN was performed on a total of 523 patients. The study included 159 patients and 214 renal units. Hydronephrosis was detected in 176 renal units and pyonephrosis in 38 renal units. No statistically significant difference was observed between the measured AP diameter and renal pelvic area in the two groups (28.45 +/- 10.1 mm vs. 31.13 +/- 14.4 mm, p = 0.36 and 658.51 +/- 433.1 mm2 vs. 755.14 +/- 470.6 mm2, p = 0.22, respectively). The mean HU value of the pyonephrosis group was significantly higher (2.30 +/- 5.02 vs. 10.97 +/- 6.68, p < 0.001). At the cut-off value of 8.46, HU had a sensitivity of 68.4% and specificity of 92.6% in the diagnosis of pyonephrosis. Conclusions It is possible to determine differential diagnosis between pyonephrosis and hydronephrosis easily and without additional cost by performing dilated renal pelvis HU measurements on NCECT.
dc.identifier.doi10.7759/cureus.11675
dc.identifier.eissn2168-8184
dc.identifier.issue11
dc.identifier.pmcidPMC7769741
dc.identifier.pmid33391912
dc.identifier.startpagee11675
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/16521
dc.identifier.volume12
dc.identifier.wosWOS:000593046000007
dc.language.isoen
dc.publisherSPRINGERNATURE
dc.relation.ispartofCUREUS JOURNAL OF MEDICAL SCIENCE
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjecthounsfield unit
dc.subjecthydronephrosis
dc.subjectnon-contrast-enhanced ct
dc.subjectpercutaneous nephrostomy
dc.subjectpyonephrosis
dc.subjectATTENUATION VALUES
dc.subjectACUTE PYELONEPHRITIS
dc.subjectSEPTIC SHOCK
dc.subjectCT
dc.subjectINFECTION
dc.subjectDIAGNOSIS
dc.subjectACCURACY
dc.subjectFLUID
dc.titleImportance of the Hounsfield Unit Value Measured by Computed Tomography in the Differentiation of Hydronephrosis and Pyonephrosis
dc.typeArticle
dspace.entity.typePublication
rdl.citation.wos10
rdl.departmentUrology, Erzincan Binali Yildirim University Faculty of Medicine, Erzincan, TUR.
rdl.oa.statusgold
rdl.source.indexWOS
rdl.source.indexPUBMED
rdl.wos.indexEmerging Sources Citation Index (ESCI)