Analysing of Harmonics Affecting the Energy Quality in Opium Alkaloids Plant's Power System

ArticleAçık Erişim

Özet

The quality of energy has been defined to control harmonics caused by non-linear loads and international standards were brought to overcome the harmonic related problems. In determining the power quality, parameters like current-voltage harmonic, transient, flicker, current and voltage imbalance between phases, K factor are examined according to these international standards. The biggest disadvantage of harmonics is that they do not affect the power quality over an individual network but also affect the entire energy system primarily neighbouring facilities. Therefore, the energy system of Opium Alkaloids Plant was examined by using measurements information of current and voltage harmonics affecting the energy quality. And, it has been determined that the harmonics have a negative impact on energy quality. According to these findings, it has been proposed to install a well-designed filter for elimination of harmonics. Besides, it has been emphasised that new hardwares and devices should be chosen to support this harmonic filtering system in the future.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/16939Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.4018/ijeoe.2016100102Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorOguz, Yuksel
dc.contributor.authorSahin, Mustafa
dc.contributor.authorGuven, Yilmaz
dc.contributor.authorTugcu, Hatice Zeliha
dc.date.accessioned2026-10-18T20:41:09.271729182Z
dc.date.available2026-10-18T20:41:09.271729182Z
dc.date.issued2016
dc.description.abstractThe quality of energy has been defined to control harmonics caused by non-linear loads and international standards were brought to overcome the harmonic related problems. In determining the power quality, parameters like current-voltage harmonic, transient, flicker, current and voltage imbalance between phases, K factor are examined according to these international standards. The biggest disadvantage of harmonics is that they do not affect the power quality over an individual network but also affect the entire energy system primarily neighbouring facilities. Therefore, the energy system of Opium Alkaloids Plant was examined by using measurements information of current and voltage harmonics affecting the energy quality. And, it has been determined that the harmonics have a negative impact on energy quality. According to these findings, it has been proposed to install a well-designed filter for elimination of harmonics. Besides, it has been emphasised that new hardwares and devices should be chosen to support this harmonic filtering system in the future.
dc.identifier.doi10.4018/ijeoe.2016100102
dc.identifier.eissn2160-9543
dc.identifier.endpage47
dc.identifier.issn2160-9500
dc.identifier.issue4
dc.identifier.startpage26
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/16939
dc.identifier.volume5
dc.identifier.wosWOS:000387883000002
dc.language.isoen
dc.publisherIGI GLOBAL
dc.relation.ispartofINTERNATIONAL JOURNAL OF ENERGY OPTIMIZATION AND ENGINEERING
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectCapacitor
dc.subjectEnergy Quality
dc.subjectHarmonics
dc.subjectPower Systems
dc.subjectReactive Power
dc.subjectEnergy & Fuels
dc.titleAnalysing of Harmonics Affecting the Energy Quality in Opium Alkaloids Plant's Power System
dc.typeArticle
dspace.entity.typePublication
rdl.citation.wos1
rdl.source.indexWOS
rdl.wos.indexEmerging Sources Citation Index (ESCI)