Normal Measurements of Optic Nerve in Pediatric Population

ArticleAçık Erişim

Özet

Objective: The aim of this study was to examine the normal values of the optic nerve in different segments of the nerve trace in the pediatric population using magnetic resonance imaging (MRI). Methods: Two radiologists retrospectively reviewed images obtained with a 1.5 tesla MR device of 426 youngsters (213 males/213 girls). Measurements were performed on the T2 sequence. Parts of the orbital region, prechiasmatic region, and optic tract were measured. Participants were divided into 5 different age groups. Results: The mean age of the population is 8.3 ± 1.5 years. The average diameter of the orbital segment of the entire population was 3.58 ± 0.53 mm, 4.74 ± 0.48 mm for the prechiasmatic segment, and 3.61 ± 0.48 mm for the optic tract section. Age correlates positively with the orbital plane (OP), prechiasmatic portion (PP), and optic tract (OT) values. All age groups have considerably varying mean OP, PP, and OP diameters. Good interobserver reliability was observed for all 3 diameter measurements (OP cap value = 0.62, PP cap value = 0.58, OT cap value = 0.67). Conclusion: Normal diameters of the optic nerve can be measured by MRI at above mentioned sections with a good interobserver reliability. These normal values can be used to detect obscure thickness changes/abnormalities in optic nerves of the children.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/17698Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.5152/abcr.2024.23161Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorFatihoglu, Erdem
dc.contributor.authorÇETİN, Türkhun
dc.contributor.authorKazci, Omer
dc.contributor.authorSenbil, Duzgun can
dc.date.accessioned2026-10-18T20:49:41.082153729Z
dc.date.available2026-10-18T20:49:41.082153729Z
dc.date.issued2024
dc.description.abstractObjective: The aim of this study was to examine the normal values of the optic nerve in different segments of the nerve trace in the pediatric population using magnetic resonance imaging (MRI). Methods: Two radiologists retrospectively reviewed images obtained with a 1.5 tesla MR device of 426 youngsters (213 males/213 girls). Measurements were performed on the T2 sequence. Parts of the orbital region, prechiasmatic region, and optic tract were measured. Participants were divided into 5 different age groups. Results: The mean age of the population is 8.3 ± 1.5 years. The average diameter of the orbital segment of the entire population was 3.58 ± 0.53 mm, 4.74 ± 0.48 mm for the prechiasmatic segment, and 3.61 ± 0.48 mm for the optic tract section. Age correlates positively with the orbital plane (OP), prechiasmatic portion (PP), and optic tract (OT) values. All age groups have considerably varying mean OP, PP, and OP diameters. Good interobserver reliability was observed for all 3 diameter measurements (OP cap value = 0.62, PP cap value = 0.58, OT cap value = 0.67). Conclusion: Normal diameters of the optic nerve can be measured by MRI at above mentioned sections with a good interobserver reliability. These normal values can be used to detect obscure thickness changes/abnormalities in optic nerves of the children.
dc.identifier.doi10.5152/abcr.2024.23161
dc.identifier.eissn2687-4482
dc.identifier.endpage11
dc.identifier.issn2687-4520
dc.identifier.issue1
dc.identifier.startpage7
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/17698
dc.identifier.volume6
dc.language.isoen
dc.relation.ispartofArchives of Basic and Clinical Research
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectGöz Hastalıkları
dc.subjectRadyoloji
dc.subjectNükleer Tıp
dc.subjectTıbbi Görüntüleme
dc.titleNormal Measurements of Optic Nerve in Pediatric Population
dc.typeArticle
dspace.entity.typePublication
rdl.citation.trdizin0
rdl.departmentERZİNCAN BİNALİ YILDIRIM ÜNİVERSİTESİ
rdl.departmentSAĞLIK BİLİMLERİ ÜNİVERSİTESİ
rdl.source.indexTRDIZIN