Artifacts in cranial MRI caused by extracranial foreign bodies and analysis of these foreign bodies

ArticleAçık Erişim

Özet

Purpose: The purpose of our study was to conduct a chemical analysis of extracranial foreign bodies (FBs) causing artifacts in cranial magnetic resonance imaging (MRI) and to investigate the association between chemical composition, magnetic susceptibility, and artifact size. Materials and Methods: A total of 12 patients were included in the study. The FBs responsible for the artifacts were visualized using cranial computed tomography (CT). Artifact-causing FBs were removed from the scalps of 10 patients and analyzed using scanning electron microscope with energy dispersive spectroscopy (SEM-EDS), X-ray diffraction spectroscopy (X-RD), and Fourier-transform infrared spectroscopy (FT-IR). The magnetic susceptibility of the samples was determined using the reference standard material MnCl2.6H2O. The volume of the MRI artifacts was measured in cubic centimeters (cm3). Results: EDS results demonstrated that the mean Fe ratio was 5.82% in the stone samples and 0.08% in the glass samples. Although no phase peaks were detected in the X-RD spectra of the glass samples, peaks of Fe2O3, Al2Ca (SiO4) were detected in the X-RD spectra of the stone samples. The FT-IR spectra revealed metal oxide peaks corresponding to Fe, Al, in the stone samples and peaks confirming Al2SiO5and Na2SiO3structures in the glass samples. The mean volumes of the MRI artifacts produced by the stone and glass samples were 5.9 cm3 and 2.5 cm3, respectively. Conclusions: Artifacts caused by extracranial FBs containing metal/metal oxide components are directly associated with their chemical composition and the artifact size are also related to element composition and magnetic susceptibility. © 2019 Indian Journal of Radiology and Imaging | Published by Wolters Kluwer-Medknow.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/13402Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.4103/ijri.ijri_211_18Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorKayaci, Selim
dc.contributor.authorTabak, Ahmet
dc.contributor.authorDurur-Subasi, Irmak
dc.contributor.authorEldes, Tugba
dc.contributor.authorKoksal, Vaner
dc.contributor.authorSirin, Murat
dc.contributor.authorArslan, Yusuf Kemal
dc.date.accessioned2026-10-18T20:28:14.307451089Z
dc.date.available2026-10-18T20:28:14.307451089Z
dc.date.issued2021
dc.description.abstractPurpose: The purpose of our study was to conduct a chemical analysis of extracranial foreign bodies (FBs) causing artifacts in cranial magnetic resonance imaging (MRI) and to investigate the association between chemical composition, magnetic susceptibility, and artifact size. Materials and Methods: A total of 12 patients were included in the study. The FBs responsible for the artifacts were visualized using cranial computed tomography (CT). Artifact-causing FBs were removed from the scalps of 10 patients and analyzed using scanning electron microscope with energy dispersive spectroscopy (SEM-EDS), X-ray diffraction spectroscopy (X-RD), and Fourier-transform infrared spectroscopy (FT-IR). The magnetic susceptibility of the samples was determined using the reference standard material MnCl2.6H2O. The volume of the MRI artifacts was measured in cubic centimeters (cm3). Results: EDS results demonstrated that the mean Fe ratio was 5.82% in the stone samples and 0.08% in the glass samples. Although no phase peaks were detected in the X-RD spectra of the glass samples, peaks of Fe2O3, Al2Ca (SiO4) were detected in the X-RD spectra of the stone samples. The FT-IR spectra revealed metal oxide peaks corresponding to Fe, Al, in the stone samples and peaks confirming Al2SiO5and Na2SiO3structures in the glass samples. The mean volumes of the MRI artifacts produced by the stone and glass samples were 5.9 cm3 and 2.5 cm3, respectively. Conclusions: Artifacts caused by extracranial FBs containing metal/metal oxide components are directly associated with their chemical composition and the artifact size are also related to element composition and magnetic susceptibility. © 2019 Indian Journal of Radiology and Imaging | Published by Wolters Kluwer-Medknow.
dc.identifier.doi10.4103/ijri.ijri_211_18
dc.identifier.eissn1998-3808
dc.identifier.endpage304
dc.identifier.issn0971-3026
dc.identifier.issue3
dc.identifier.pmcidPMC6857268
dc.identifier.pmid31741599
dc.identifier.scopus2-s2.0-85074695382
dc.identifier.startpage299
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/13402
dc.identifier.volume29
dc.identifier.wosWOS:000502070700011
dc.language.isoen
dc.publisherWolters Kluwer Medknow Publications
dc.relation.ispartofIndian Journal of Radiology and Imaging
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectArtifact
dc.subjectglass
dc.subjectmagnetic resonance imaging
dc.subjectmagnetism
dc.subjectstone
dc.subjectiron oxide
dc.subjectmanganese chloride
dc.subjectsilicon dioxide
dc.subjectwater
dc.subjectArticle
dc.subjectchemical composition
dc.subjectclinical article
dc.subjectcomputer assisted tomography
dc.subjectenergy dispersive X ray spectroscopy
dc.subjectextracranial foreign body
dc.subjectforeign body
dc.subjectFourier transform infrared spectroscopy
dc.subjecthuman
dc.subjectimage artifact
dc.subjectneuroimaging
dc.subjectnuclear magnetic resonance imaging
dc.subjectprospective study
dc.subjectscanning electron microscopy
dc.subjectX ray diffraction
dc.subjectX ray spectroscopy
dc.titleArtifacts in cranial MRI caused by extracranial foreign bodies and analysis of these foreign bodies
dc.typeArticle
dspace.entity.typePublication
rdl.citation.scopus4
rdl.citation.wos2
rdl.departmentDepartment of Neurosurgery, Erzincan University, Erzincan, Turkey. | Department of Biostatistics, Faculty of Medicine, Erzincan University, Erzincan, Turkey.
rdl.oa.statusgold
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.source.indexPUBMED
rdl.wos.indexEmerging Sources Citation Index (ESCI)