Determination of L X-ray fluorescence cross-sections in the atomic range of elements 57 ≤ Z ≤ 69 in an external magnetic field

ArticleAçık Erişim

Özet

L X-ray fluorescence cross sections have been determined for La, Ce, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er and Tm elements at the magnetic field (B = 0.8 Tesla) and without magnetic field with energy dispersive X-ray fluorescence spectroscopy (EDXRF) technique. The fluorescence spectra were obtained by using Si(Li) solid-state detector with a high resolution and 241Am radioactive point source (with 59.5 keV γ-rays). The results have been compared with the theoretical results without the magnetic field. It has been observed a good agreement between the experimental and the theoretical results and that L X-ray fluorescence cross sections of Lanthanide elements change with the magnetic field except σLl of Gd, σLβ of Dy and σLγ of Ce and Tm. © 2021

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/13425Resmi atıflarda kullanılan kalıcı adres
Tam Kayıt
AlanDeğerDil
dc.contributor.authorUğurlu, Mine
dc.contributor.authorAkkuş, Tuba
dc.contributor.authorDemir, Lütfü
dc.date.accessioned2026-10-18T20:28:15.387454345Z
dc.date.available2026-10-18T20:28:15.387454345Z
dc.date.issued2021
dc.description.abstractL X-ray fluorescence cross sections have been determined for La, Ce, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er and Tm elements at the magnetic field (B = 0.8 Tesla) and without magnetic field with energy dispersive X-ray fluorescence spectroscopy (EDXRF) technique. The fluorescence spectra were obtained by using Si(Li) solid-state detector with a high resolution and 241Am radioactive point source (with 59.5 keV γ-rays). The results have been compared with the theoretical results without the magnetic field. It has been observed a good agreement between the experimental and the theoretical results and that L X-ray fluorescence cross sections of Lanthanide elements change with the magnetic field except σLl of Gd, σLβ of Dy and σLγ of Ce and Tm. © 2021
dc.description.sponsorshipFunding text 1: This work was supported by the Atatürk University Research Fund , project No. FBA-2019–7184 . ; Funding text 2: This work was supported by the Atat?rk University Research Fund, project No. FBA-2019?7184. Prof. Dr. L?tf? Demir has helped with the use of XRF laboratory of Atat?rk University, sample purchase, preparation of samples, preparation of experimental set-up, performing measurements and evaluating the results. Dr. Mine U?urlu and Dr Tuba Akku? took part in the preparation of the samples, performing measurements, making calculations, evaluating the results and writing the article.
dc.identifier.doi10.1016/j.molstruc.2021.130900
dc.identifier.eissn1872-8014
dc.identifier.issn0022-2860
dc.identifier.scopus2-s2.0-85108682806
dc.identifier.startpage130900
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/13425
dc.identifier.volume1244
dc.identifier.wosWOS:000702511400011
dc.language.isoen
dc.publisherElsevier B.V.
dc.relation.ispartofJournal of Molecular Structure
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectLanthanides
dc.subjectMagnetic field
dc.subjectX-ray intensity ratios
dc.subjectEnergy dispersive spectroscopy
dc.subjectFluorescence
dc.subjectFluorescence spectroscopy
dc.subjectGamma rays
dc.subjectRadioactivity
dc.subjectRare earth elements
dc.subjectSemiconductor detectors
dc.subjectX ray detectors
dc.subjectEnergy dispersive X-ray fluorescence
dc.subjectExternal magnetic field
dc.subjectFluorescence spectra
dc.subjectFluorescence spectroscopy techniques
dc.subjectL X-rays
dc.subjectLi$++$
dc.subjectMagnetic-field
dc.subjectX ray fluorescence
dc.subjectX ray fluorescence spectroscopy
dc.subjectMagnetic fields
dc.titleDetermination of L X-ray fluorescence cross-sections in the atomic range of elements 57 ≤ Z ≤ 69 in an external magnetic field
dc.typeArticle
dspace.entity.typePublication
rdl.citation.scopus1
rdl.citation.wos2
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)