The levels effect of the voltage generated by an inverter with partial source on distortion

ArticleAçık Erişim

Özet

It is very important that the quality of the energy obtained is at a high level while alternating energy is obtained from the direct current energy source. In order to improve the energy quality by reducing the harmonics in the generation of the alternating current, numerous studies have been done on multi-level inverter hardware structures and switching techniques. However, the effect of the slope formed by the difference between the levels in the generated multi-level alternating voltage structure on the resulting harmonic distortions has not been studied so far. So, the paper researches the effects of the inclination between the levels of the alternating voltage generated on load by the inverter. Firstly, after the multi-level inverter structure which can produce four levels of voltage is determined, the operation of this inverter is given in the tabular form. The value of voltage formation gradients (VFG) is calculated according to a generation of multi-level voltages with different amplitude sizes between the levels of the voltage on the R L load after simulation of the system is performed at the Matlab Simulink. After that, obtained load voltages at the simulation are validated in the experiment. The effects of these gradients on the quality of the voltages are determined by measuring harmonic distortions. When the distortion values obtained according to the slope of the alternating voltage structures are analysed, it is seen that the distortion values change significantly as the slope changes. Harmonic distortion caused by VFGs gives the appropriate source values that form voltage levels for the system. Therefore, if the harmonic distortion of the current produced in the load is to be reduced or eliminated, voltage levels of alternating must be generated according to the proposed VFG method. © 2020 Informa UK Limited, trading as Taylor & Francis Group.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/13727Resmi atıflarda kullanılan kalıcı adres
Tam Kayıt
AlanDeğerDil
dc.contributor.authorCan, Erol
dc.date.accessioned2026-10-18T20:28:33.087157551Z
dc.date.available2026-10-18T20:28:33.087157551Z
dc.date.issued2020
dc.description.abstractIt is very important that the quality of the energy obtained is at a high level while alternating energy is obtained from the direct current energy source. In order to improve the energy quality by reducing the harmonics in the generation of the alternating current, numerous studies have been done on multi-level inverter hardware structures and switching techniques. However, the effect of the slope formed by the difference between the levels in the generated multi-level alternating voltage structure on the resulting harmonic distortions has not been studied so far. So, the paper researches the effects of the inclination between the levels of the alternating voltage generated on load by the inverter. Firstly, after the multi-level inverter structure which can produce four levels of voltage is determined, the operation of this inverter is given in the tabular form. The value of voltage formation gradients (VFG) is calculated according to a generation of multi-level voltages with different amplitude sizes between the levels of the voltage on the R L load after simulation of the system is performed at the Matlab Simulink. After that, obtained load voltages at the simulation are validated in the experiment. The effects of these gradients on the quality of the voltages are determined by measuring harmonic distortions. When the distortion values obtained according to the slope of the alternating voltage structures are analysed, it is seen that the distortion values change significantly as the slope changes. Harmonic distortion caused by VFGs gives the appropriate source values that form voltage levels for the system. Therefore, if the harmonic distortion of the current produced in the load is to be reduced or eliminated, voltage levels of alternating must be generated according to the proposed VFG method. © 2020 Informa UK Limited, trading as Taylor & Francis Group.
dc.identifier.doi10.1080/00207217.2020.1726496
dc.identifier.eissn1362-3060
dc.identifier.endpage1435
dc.identifier.issn0020-7217
dc.identifier.issue9
dc.identifier.scopus2-s2.0-85079789009
dc.identifier.startpage1414
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/13727
dc.identifier.volume107
dc.identifier.wosWOS:000514876100001
dc.language.isoen
dc.publisherTaylor and Francis Ltd.
dc.relation.ispartofInternational Journal of Electronics
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectQuality of energy
dc.subjectthe appropriate source values
dc.subjectvoltage formation gradients
dc.subjectHarmonic analysis
dc.subjectHarmonic distortion
dc.subjectMATLAB
dc.subjectAlternating current
dc.subjectAlternating voltages
dc.subjectDirect current
dc.subjectMATLAB/ SIMULINK
dc.subjectMultilevel inverter
dc.subjectQuality of energies
dc.subjectSwitching techniques
dc.subjectElectric inverters
dc.titleThe levels effect of the voltage generated by an inverter with partial source on distortion