Mean atomic number analysis by the coherent to backscattering intensity ratios at 59.54 and 661.62 photon energies

ArticleAçık Erişim

Özet

In this work, the qualitative analysis has been performed by using ratio of coherent to backscattering intensity ratios. The samples in the mean atomic number range 4.268≤Z‾≤5.786 and 9.743≤Z‾≤83.00 were prepared by using dilution technique. 59.54 and 661.62 keV photon energies are obtained from the radioactive point sources of 241Am and 137Cs an activity of 0.43–0.20 MBq, respectively. The scattered gamma rays were counted by a HPGe detector with a resolution of 182 eV at 5.9 keV. The obtained intensity ratios are plotted as function of the mean atomic number and constituted a best-fit-curve. The correlation coefficients for the prepared samples in the mean atomic number range 4.268≤Z‾≤5.786 are 0.976 and 0.970 at 59.54 and 661.62 keV photons, respectively. The correlation coefficients for the prepared samples in the mean atomic number range 9.743≤Z‾≤83.00 are 0.964 and 0.967 at 59.54 and 661.62 keV photons, respectively. It is observed that there was a high correlation between coherent to backscattering intensity ratio and the mean atomic numbers. It was concluded that the recommended intensity ratio can be used for qualitative analysis. © 2019 Elsevier Ltd

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/13851Resmi atıflarda kullanılan kalıcı adres
Tam Kayıt
AlanDeğerDil
dc.contributor.authorAkkuş, Tuba
dc.contributor.authorYılmaz, Demet
dc.date.accessioned2026-10-18T20:28:39.284738525Z
dc.date.available2026-10-18T20:28:39.284738525Z
dc.date.issued2020
dc.description.abstractIn this work, the qualitative analysis has been performed by using ratio of coherent to backscattering intensity ratios. The samples in the mean atomic number range 4.268≤Z‾≤5.786 and 9.743≤Z‾≤83.00 were prepared by using dilution technique. 59.54 and 661.62 keV photon energies are obtained from the radioactive point sources of 241Am and 137Cs an activity of 0.43–0.20 MBq, respectively. The scattered gamma rays were counted by a HPGe detector with a resolution of 182 eV at 5.9 keV. The obtained intensity ratios are plotted as function of the mean atomic number and constituted a best-fit-curve. The correlation coefficients for the prepared samples in the mean atomic number range 4.268≤Z‾≤5.786 are 0.976 and 0.970 at 59.54 and 661.62 keV photons, respectively. The correlation coefficients for the prepared samples in the mean atomic number range 9.743≤Z‾≤83.00 are 0.964 and 0.967 at 59.54 and 661.62 keV photons, respectively. It is observed that there was a high correlation between coherent to backscattering intensity ratio and the mean atomic numbers. It was concluded that the recommended intensity ratio can be used for qualitative analysis. © 2019 Elsevier Ltd
dc.identifier.doi10.1016/j.apradiso.2019.108926
dc.identifier.eissn1872-9800
dc.identifier.issn0969-8043
dc.identifier.pmid31622843
dc.identifier.scopus2-s2.0-85073105911
dc.identifier.startpage108926
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/13851
dc.identifier.volume155
dc.identifier.wosWOS:000502882400013
dc.language.isoen
dc.publisherElsevier Ltd
dc.relation.ispartofApplied Radiation and Isotopes
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectBackscattering
dc.subjectDilution
dc.subjectGamma rays
dc.subjectMean atomic number
dc.subjectQualitative analysis
dc.subjectGermanium compounds
dc.subjectPhosphorus compounds
dc.subjectPhotons
dc.subjectRadioactivity
dc.subjectamericium 241
dc.subjectcesium 137
dc.subjectAtomic numbers
dc.subjectBackscattering intensity
dc.subjectCorrelation coefficient
dc.subjectDilution technique
dc.subjectHPGe detectors
dc.subjectIntensity ratio
dc.subjectPoint sources
dc.subjectArticle
dc.subjectchemical parameters
dc.subjectcoherent to backscattering intensity ratio
dc.subjectcontrolled study
dc.subjectgamma radiation
dc.subjectphoton
dc.subjectpriority journal
dc.subjectradiation scattering
dc.subjectradiological parameters
dc.subjectAtoms
dc.titleMean atomic number analysis by the coherent to backscattering intensity ratios at 59.54 and 661.62 photon energies
dc.typeArticle
dspace.entity.typePublication
rdl.citation.scopus3
rdl.citation.wos3
rdl.departmentDepartment of Physics, Faculty of Arts and Sciences, Erzincan Binali Yıldırım University, Erzincan, 24100, Turkey. Electronic address: takkus@erzincan.edu.tr.
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.source.indexPUBMED
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)