The magnetic field effect of K X-ray fluorescence parameters of elements in the range 39 ≤ z ≤48

ArticleAçık Erişim

Özet

In this work, the fluorescence parameters (the fluorescence cross section (б), the fluorescence yield (ὡ), and vacancy transfer probability (ή)) of the fifth period elements, which have great potential to be developed as a technology, are investigated by taking advantage of interactions between atoms and radiation. For this process, the samples were excited via241Am source without magnetic field and in the external magnetic field. The radiation emitted from targets was collected by an Si(Li) detector and energy channels were located on a computer program by means of a multi-channel analyzer. The data on the computer program were analyzed for calculations. The discrepancies have been observed between the experimental results and the theoretical results calculated without magnetic field. It was determined that results changed with the magnetic field (B = 0.4 and 0.8 T) and the variation of the X-ray fluorescence (XRF) parameters with the magnetic field for diamagnetic Ag and Cd is lower than for paramagnetic elements. © 2020, Canadian Science Publishing. All rights reserved.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/13867Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1139/cjp-2019-0296Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorUğurlu, Mine
dc.contributor.authorAkkuş, Tuba
dc.contributor.authorDemir, Lütfü
dc.date.accessioned2026-10-18T20:28:40.172691696Z
dc.date.available2026-10-18T20:28:40.172691696Z
dc.date.issued2020
dc.description.abstractIn this work, the fluorescence parameters (the fluorescence cross section (б), the fluorescence yield (ὡ), and vacancy transfer probability (ή)) of the fifth period elements, which have great potential to be developed as a technology, are investigated by taking advantage of interactions between atoms and radiation. For this process, the samples were excited via241Am source without magnetic field and in the external magnetic field. The radiation emitted from targets was collected by an Si(Li) detector and energy channels were located on a computer program by means of a multi-channel analyzer. The data on the computer program were analyzed for calculations. The discrepancies have been observed between the experimental results and the theoretical results calculated without magnetic field. It was determined that results changed with the magnetic field (B = 0.4 and 0.8 T) and the variation of the X-ray fluorescence (XRF) parameters with the magnetic field for diamagnetic Ag and Cd is lower than for paramagnetic elements. © 2020, Canadian Science Publishing. All rights reserved.
dc.description.sponsorshipThis work was supported by the Atatürk University Research Fund, project No. 2015/99.
dc.identifier.doi10.1139/cjp-2019-0296
dc.identifier.eissn1208-6045
dc.identifier.endpage221
dc.identifier.issn0008-4204
dc.identifier.issue2
dc.identifier.scopus2-s2.0-85078968142
dc.identifier.startpage217
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/13867
dc.identifier.volume98
dc.identifier.wosWOS:000512303200016
dc.language.isoen
dc.publisherCanadian Science Publishing
dc.relation.ispartofCanadian Journal of Physics
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectFluorescence parameters
dc.subjectMagnetic field
dc.subjectRadioactive source
dc.subjectSi(Li) detector
dc.subjectFluorescence
dc.subjectRadioactivity
dc.subjectX rays
dc.subjectExternal magnetic field
dc.subjectFluorescence yield
dc.subjectMulti-channel analyzer
dc.subjectRadioactive sources
dc.subjectSi detectors
dc.subjectVacancy transfer probabilities
dc.subjectX ray fluorescence
dc.subjectMagnetic fields
dc.titleThe magnetic field effect of K X-ray fluorescence parameters of elements in the range 39 ≤ z ≤48
dc.typeArticle
dspace.entity.typePublication
rdl.citation.scopus5
rdl.citation.wos5
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)