Seismic Performance Assessment of a Corroded 50-Year-Old Reinforced Concrete Building

ArticleAçık Erişim

Özet

Deterioration due to corrosion becomes a more serious problem when future earthquakes with unpredicted intensity and time are considered. Therefore, the prediction of performance levels of corroded reinforced concrete structures is important to prevent serious premature damage. In this study, a corroded, 50-year-old high school building was analyzed by considering corrosion effects and is presented here as a case study. The relevant data obtained from the structure were used to predict its performance level for different time periods by combining two major effects of corrosion. Deformation due to bond-slip relationships and loss in cross-sectional areas of reinforcement bars were examined as a function of corrosion rate for five corrosion levels. Plastic hinges were defined as a consequence of corrosion effects, and they were used to perform nonlinear push-over analyses. Incremental dynamic analysis was then performed for 20 individual earthquake ground motion records to predict the structure's time-dependent performance levels as a function of corrosion rate. Results showed that corrosion had a serious effect on the performance levels of the school building considered in this study by decreasing bond strength. (C) 2015 American Society of Civil Engineers.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/16606Resmi atıflarda kullanılan kalıcı adres
Tam Kayıt
AlanDeğerDil
dc.contributor.authorYalciner, Hakan
dc.contributor.authorSensoy, Serhan
dc.contributor.authorEren, Ozgur
dc.date.accessioned2026-10-18T20:36:29.058419021Z
dc.date.available2026-10-18T20:36:29.058419021Z
dc.date.issued2015
dc.description.abstractDeterioration due to corrosion becomes a more serious problem when future earthquakes with unpredicted intensity and time are considered. Therefore, the prediction of performance levels of corroded reinforced concrete structures is important to prevent serious premature damage. In this study, a corroded, 50-year-old high school building was analyzed by considering corrosion effects and is presented here as a case study. The relevant data obtained from the structure were used to predict its performance level for different time periods by combining two major effects of corrosion. Deformation due to bond-slip relationships and loss in cross-sectional areas of reinforcement bars were examined as a function of corrosion rate for five corrosion levels. Plastic hinges were defined as a consequence of corrosion effects, and they were used to perform nonlinear push-over analyses. Incremental dynamic analysis was then performed for 20 individual earthquake ground motion records to predict the structure's time-dependent performance levels as a function of corrosion rate. Results showed that corrosion had a serious effect on the performance levels of the school building considered in this study by decreasing bond strength. (C) 2015 American Society of Civil Engineers.
dc.identifier.doi10.1061/(asce)st.1943-541x.0001263
dc.identifier.eissn1943-541X
dc.identifier.issn0733-9445
dc.identifier.issue12
dc.identifier.startpageUNSP 05015001
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/16606
dc.identifier.volume141
dc.identifier.wosWOS:000365128300001
dc.language.isoen
dc.publisherASCE-AMER SOC CIVIL ENGINEERS
dc.relation.ispartofJOURNAL OF STRUCTURAL ENGINEERING
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectCorrosion
dc.subjectPlastic hinges
dc.subjectSlip
dc.subjectSeismic analysis
dc.subjectSeismic effects
dc.subjectSUBJECT
dc.subjectMODELS
dc.subjectConstruction & Building Technology
dc.subjectEngineering, Civil
dc.subjectEngineering
dc.titleSeismic Performance Assessment of a Corroded 50-Year-Old Reinforced Concrete Building
dc.typeArticle
dspace.entity.typePublication
rdl.citation.wos44
rdl.oa.statusgreen
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)