Determination of electrochemical and wettability properties of TiN coated 316L stainless steel implant material by cathodic arc PVD method

ArticleAçık Erişim

Özet

In this study, TiN films were coated on the surface by cathodic arc physical vapor deposition (CAPVD) method in order to improve the corrosion resistance and hydrophobic properties of 316L stainless steel, which is used as a biomaterial. The surface morphology, surface composition, corrosion resistance, and wettability of the coated samples were characterized and the characterization of the coatings was done by XRD, SEM and EDS. After electrochemical experiments in simulated body fluid ( SBF) solution, it was observed that the corrosion resistance of the coating film increased. In addition, contact angle measurements were taken with distilled water, n-hexadecane, ethylene glycol, and SBF solutions to determine the wettability and free surface energy properties of untreated and coated samples. The hydrophobic and oleophobic properties of the surfaces were obtained after the coating film, and the contact angle value increased from 92° to 119° after the contact angle measurement with the SBF solution. According to the measured contact angle values, the surface free energy values of the untreated and TiN coated stainless steel samples were calculated as 26.7 mN/m and 18.5 mN/m, respectively, according to the measured contact angle values.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/18072Resmi atıflarda kullanılan kalıcı adres
Tam Kayıt
AlanDeğerDil
dc.contributor.authorÇAKIR, MEVRA ASLAN
dc.date.accessioned2026-10-18T20:56:21.200717185Z
dc.date.available2026-10-18T20:56:21.200717185Z
dc.date.issued2023
dc.description.abstractIn this study, TiN films were coated on the surface by cathodic arc physical vapor deposition (CAPVD) method in order to improve the corrosion resistance and hydrophobic properties of 316L stainless steel, which is used as a biomaterial. The surface morphology, surface composition, corrosion resistance, and wettability of the coated samples were characterized and the characterization of the coatings was done by XRD, SEM and EDS. After electrochemical experiments in simulated body fluid ( SBF) solution, it was observed that the corrosion resistance of the coating film increased. In addition, contact angle measurements were taken with distilled water, n-hexadecane, ethylene glycol, and SBF solutions to determine the wettability and free surface energy properties of untreated and coated samples. The hydrophobic and oleophobic properties of the surfaces were obtained after the coating film, and the contact angle value increased from 92° to 119° after the contact angle measurement with the SBF solution. According to the measured contact angle values, the surface free energy values of the untreated and TiN coated stainless steel samples were calculated as 26.7 mN/m and 18.5 mN/m, respectively, according to the measured contact angle values.
dc.identifier.doi10.17714/gumusfenbil.1167635
dc.identifier.eissn2146-538X
dc.identifier.endpage115
dc.identifier.issue1
dc.identifier.startpage106
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/18072
dc.identifier.volume13
dc.language.isotr
dc.relation.ispartofGümüşhane Üniversitesi Fen Bilimleri Dergisi
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectMalzeme Bilimleri
dc.subjectÖzellik ve Test
dc.subjectBiyomalzemeler
dc.titleDetermination of electrochemical and wettability properties of TiN coated 316L stainless steel implant material by cathodic arc PVD method
dc.typeArticle
dspace.entity.typePublication
rdl.citation.trdizin1
rdl.departmentERZİNCAN BİNALİ YILDIRIM ÜNİVERSİTESİ
rdl.source.indexTRDIZIN