Flame and instability characteristics of high hydrogen content gas mixtures

ArticleAçık Erişim

Özet

In this study, initially, 50%H2–25%CH4–25%CO2, 60%H2–20%CH4–20%CO2 and 70%H2–15%CH4–15%CO2 mixtures were combusted in a laboratory scale-swirl stabilized-premixed combustor so as to specify combustion and emission characteristics of respective gas mixtures. Later on, such mixture flames were exposed to acoustic perturbations at different frequencies between the values of 65–205 Hz and under these conditions, flame response was evaluated. The acoustic perturbations were intentionally created by loudspeakers located in side arms of the T-shaped combustor. Two openings on the combustor walls, and photodiodes and pressure sensors assembled in the experimental apparatus enabled interpreting flame response. During experiments, inlet parameters (such as thermal power – 4 kW, equivalence ratio – 0.5, mixture temperature, etc.) and geometric swirl number (1.2) were kept constant, and tested flames were acoustically forced for 30 s at each frequency step. Results showed that thermal Zeldovich mechanism doesn't dominate NOx formation for tested flames, and 50%H2–25%CH4–25%CO2 mixture emits nearly thirty times of magnitude of higher NO than 70%H2–15%CH4–15%CO2 mixture. Besides, the onset of flame instabilities depending on the forcing frequency isn't controlled by gas composition. However, flame and combustion chamber acoustics weakly couple, hence pressure and heat release rate oscillations weaken as hydrogen amount in gas mixture increases. © 2021 Elsevier Ltd

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/13498Resmi atıflarda kullanılan kalıcı adres
Tam Kayıt
AlanDeğerDil
dc.contributor.authorYilmaz, Harun
dc.contributor.authorYilmaz, Ilker
dc.date.accessioned2026-10-18T20:28:19.857903153Z
dc.date.available2026-10-18T20:28:19.857903153Z
dc.date.issued2021
dc.description.abstractIn this study, initially, 50%H2–25%CH4–25%CO2, 60%H2–20%CH4–20%CO2 and 70%H2–15%CH4–15%CO2 mixtures were combusted in a laboratory scale-swirl stabilized-premixed combustor so as to specify combustion and emission characteristics of respective gas mixtures. Later on, such mixture flames were exposed to acoustic perturbations at different frequencies between the values of 65–205 Hz and under these conditions, flame response was evaluated. The acoustic perturbations were intentionally created by loudspeakers located in side arms of the T-shaped combustor. Two openings on the combustor walls, and photodiodes and pressure sensors assembled in the experimental apparatus enabled interpreting flame response. During experiments, inlet parameters (such as thermal power – 4 kW, equivalence ratio – 0.5, mixture temperature, etc.) and geometric swirl number (1.2) were kept constant, and tested flames were acoustically forced for 30 s at each frequency step. Results showed that thermal Zeldovich mechanism doesn't dominate NOx formation for tested flames, and 50%H2–25%CH4–25%CO2 mixture emits nearly thirty times of magnitude of higher NO than 70%H2–15%CH4–15%CO2 mixture. Besides, the onset of flame instabilities depending on the forcing frequency isn't controlled by gas composition. However, flame and combustion chamber acoustics weakly couple, hence pressure and heat release rate oscillations weaken as hydrogen amount in gas mixture increases. © 2021 Elsevier Ltd
dc.description.sponsorshipThe authors would like to thank The Scientific and Technological Research Council of Turkey ( TÜBİTAK-MAG-215M821 ) for its financial support.
dc.identifier.doi10.1016/j.energy.2021.120084
dc.identifier.eissn1873-6785
dc.identifier.issn0360-5442
dc.identifier.scopus2-s2.0-85100904328
dc.identifier.startpage120084
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/13498
dc.identifier.volume223
dc.identifier.wosWOS:000637967800008
dc.language.isoen
dc.publisherElsevier Ltd
dc.relation.ispartofEnergy
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectAcoustic perturbations
dc.subjectFlame characteristics
dc.subjectFlame instability
dc.subjectFlame response
dc.subjectH<sub>2</sub> addition
dc.subjectCarbon dioxide
dc.subjectCombustion
dc.subjectCombustors
dc.subjectGas mixtures
dc.subjectHydrogen
dc.subjectLoudspeakers
dc.subjectDifferent frequency
dc.subjectEmission characteristics
dc.subjectEquivalence ratios
dc.subjectExperimental apparatus
dc.subjectForcing frequencies
dc.subjectHeat Release Rate (HRR)
dc.subjectInstability characteristics
dc.subjectequipment
dc.subjectinstability
dc.subjectlaboratory method
dc.subjectGases
dc.titleFlame and instability characteristics of high hydrogen content gas mixtures
dc.typeArticle
dspace.entity.typePublication
rdl.citation.scopus14
rdl.citation.wos13
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)