Calibration of a potentiometric multi-sensor array for the determination of Na+, K+ and NH4+ ions by using artificial neural networks

ArticleAçık Erişim

Özet

A potentiometric multi-sensor array, comprising of all-solid-state selective and non-selective electrodes, was constituted and calibrated via artificial neural networks (ANNs) for the determinations of NH4 +, Na+ and K+ ions in aqueous model solutions. Various artificial neural network configurations were constituted and their root mean square errors of calibration (RMSEC) and root mean square errors of prediction (RMSEP) values were calculated. The model which has the lowest RMSECxRMSEP value was preferred as the best model. Artificial neural network models calculated for Na+ and K+ have nearly similar prediction ability to univariate calibrations which were performed using the main ion concentrations of the calibration solutions and respective ion-selective electrode responses. Artificial neural network model calculated for NH4+ had the superior prediction ability when compared with its univariate calibration model.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/15598Resmi atıflarda kullanılan kalıcı adres
Tam Kayıt
AlanDeğerDil
dc.contributor.authorColdur, Fatih
dc.contributor.authorAndac, Muberra
dc.date.accessioned2026-10-18T20:30:26.973582866Z
dc.date.available2026-10-18T20:30:26.973582866Z
dc.date.issued2012
dc.description.abstractA potentiometric multi-sensor array, comprising of all-solid-state selective and non-selective electrodes, was constituted and calibrated via artificial neural networks (ANNs) for the determinations of NH4 +, Na+ and K+ ions in aqueous model solutions. Various artificial neural network configurations were constituted and their root mean square errors of calibration (RMSEC) and root mean square errors of prediction (RMSEP) values were calculated. The model which has the lowest RMSECxRMSEP value was preferred as the best model. Artificial neural network models calculated for Na+ and K+ have nearly similar prediction ability to univariate calibrations which were performed using the main ion concentrations of the calibration solutions and respective ion-selective electrode responses. Artificial neural network model calculated for NH4+ had the superior prediction ability when compared with its univariate calibration model.
dc.identifier.endpage3864
dc.identifier.issn0970-7077
dc.identifier.issue9
dc.identifier.scopus2-s2.0-84861691263
dc.identifier.startpage3859
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/15598
dc.identifier.volume24
dc.language.isoen
dc.publisherChemical Publishing Co.
dc.relation.ispartofAsian Journal of Chemistry
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectArtificial neural networks
dc.subjectMulti-sensor array
dc.subjectMultivariate calibration
dc.subjectNon-linear calibration
dc.subjectPotentiometry
dc.titleCalibration of a potentiometric multi-sensor array for the determination of Na+, K+ and NH4+ ions by using artificial neural networks
dc.typeArticle
dspace.entity.typePublication
rdl.citation.scopus0
rdl.source.indexSCOPUS