Measurement of relative K X-ray intensity ratio following radioactive decay and photoionization

ArticleAçık Erişim

Özet

The measurements of the K X-ray intensity ratio I(Kα2/Kα1), I(Kβ1/Kα1) and I(Kβ/Kα) for elements V, Mn, Zn, Tc, Ru, Cd, Xe, Ba, Cs, Hg and Rn were experimentally determined both by photon excitation, in which 59.5 keV γ-rays from a 241Am and 123.6 keV γ-rays from a 60Co were used, and following the radioactive decay of 51Cr, 55Fe, 67Ga, 99Tc, 111In, 131I, 133Ba, 133Xe, 137Cs, 201Tl and 226Ra. K X-rays emitted by samples were counted by a Si(Li) detector with resolution 160 eV at 5.9 keV. Obtained values were compared with the theoretical values. It was observed that present values agree with the previous theoretical and other experimental results. © 2006 Elsevier B.V. All rights reserved.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/16135Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1016/j.nimb.2006.11.051Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorYalçin, P.
dc.date.accessioned2026-10-18T20:30:57.078222574Z
dc.date.available2026-10-18T20:30:57.078222574Z
dc.date.issued2007
dc.description.abstractThe measurements of the K X-ray intensity ratio I(Kα2/Kα1), I(Kβ1/Kα1) and I(Kβ/Kα) for elements V, Mn, Zn, Tc, Ru, Cd, Xe, Ba, Cs, Hg and Rn were experimentally determined both by photon excitation, in which 59.5 keV γ-rays from a 241Am and 123.6 keV γ-rays from a 60Co were used, and following the radioactive decay of 51Cr, 55Fe, 67Ga, 99Tc, 111In, 131I, 133Ba, 133Xe, 137Cs, 201Tl and 226Ra. K X-rays emitted by samples were counted by a Si(Li) detector with resolution 160 eV at 5.9 keV. Obtained values were compared with the theoretical values. It was observed that present values agree with the previous theoretical and other experimental results. © 2006 Elsevier B.V. All rights reserved.
dc.identifier.doi10.1016/j.nimb.2006.11.051
dc.identifier.endpage186
dc.identifier.issn0168-583X
dc.identifier.issue2
dc.identifier.scopus2-s2.0-33846294796
dc.identifier.startpage182
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/16135
dc.identifier.volume254
dc.identifier.wosWOS:000244513800002
dc.language.isoen
dc.publisherELSEVIER SCIENCE BV
dc.relation.ispartofNuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectIntensity ratio by photoionization
dc.subjectIntensity ratio following radioactive decay
dc.subjectK X-ray intensity ratio
dc.subjectDetectors
dc.subjectGamma rays
dc.subjectPhotoionization
dc.subjectPhotons
dc.subjectRadioactivity
dc.subjectSilicon sensors
dc.subjectTransition metals
dc.subjectX ray scattering
dc.titleMeasurement of relative K X-ray intensity ratio following radioactive decay and photoionization
dc.typeArticle
dspace.entity.typePublication
rdl.citation.scopus22
rdl.citation.wos23
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)