A Comparison of Needle Types and Biopsy Techniques Used in Liver Biopsies of Chronic Hepatitis B Patients

ArticleAçık Erişim

Özet

Objectives: To investigate the effect of the biopsy technique used in percutaneous liver biopsies applied with semi-automatic 16 gauge (G) and 18G Tru-cut and Menghini aspiration needles in patients with chronic hepatitis B (CHB) on pathological evaluation. Materials and Methods: The study included 104 cases diagnosed with CHB who underwent liver biopsy between 2013 and 2018. The pathology results of biopsies were evaluated with the Menghini technique under ultrasound (USG) guidance (n=26), and with 16G (n=54) and 18G (n=24) semi-automatic Tru-cut needles under USG. Results: The fibrosis score in 5 (9.3%) of the 16G cases and in 3 (12.5%) of the 18G cases, and the ISHAK score in 3 (5.6%) of the 16G and in 1 (4.2%) of the 18G cases could not be determined. There was no significant difference between the methods and needle types in terms of the number of pieces, number of portal sites, fibrosis and ISHAK score (p>0.05). There was a statistically significant difference between the biopsies performed with Menghini method and Tru-cut method with 16G and 18G (p<0.0001) in terms of material length. The diagnosis rates for the Menghini technique, and 16G and 18G Tru-cut needles were 100%, 90.7% and 83.3%, respectively, with no statistically significant difference determined (p>0.05). Conclusion: Although a larger tissue piece is obtained with the Menghini technique, allowing evaluation of a larger portal area, no significant difference was determined between the techniques in the pathological evaluation. Taking patient safety and comfort into consideration, Tru-cut needle biopsy under USG guidance is recommended rather than the Menghini technique as less trauma is created.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/16510Resmi atıflarda kullanılan kalıcı adres
Tam Kayıt
AlanDeğerDil
dc.contributor.authorKaravas, Erdal
dc.contributor.authorKarakecili, Faruk
dc.contributor.authorBalci, Mecdi Gurhan
dc.date.accessioned2026-10-18T20:36:23.476160059Z
dc.date.available2026-10-18T20:36:23.476160059Z
dc.date.issued2019
dc.description.abstractObjectives: To investigate the effect of the biopsy technique used in percutaneous liver biopsies applied with semi-automatic 16 gauge (G) and 18G Tru-cut and Menghini aspiration needles in patients with chronic hepatitis B (CHB) on pathological evaluation. Materials and Methods: The study included 104 cases diagnosed with CHB who underwent liver biopsy between 2013 and 2018. The pathology results of biopsies were evaluated with the Menghini technique under ultrasound (USG) guidance (n=26), and with 16G (n=54) and 18G (n=24) semi-automatic Tru-cut needles under USG. Results: The fibrosis score in 5 (9.3%) of the 16G cases and in 3 (12.5%) of the 18G cases, and the ISHAK score in 3 (5.6%) of the 16G and in 1 (4.2%) of the 18G cases could not be determined. There was no significant difference between the methods and needle types in terms of the number of pieces, number of portal sites, fibrosis and ISHAK score (p>0.05). There was a statistically significant difference between the biopsies performed with Menghini method and Tru-cut method with 16G and 18G (p<0.0001) in terms of material length. The diagnosis rates for the Menghini technique, and 16G and 18G Tru-cut needles were 100%, 90.7% and 83.3%, respectively, with no statistically significant difference determined (p>0.05). Conclusion: Although a larger tissue piece is obtained with the Menghini technique, allowing evaluation of a larger portal area, no significant difference was determined between the techniques in the pathological evaluation. Taking patient safety and comfort into consideration, Tru-cut needle biopsy under USG guidance is recommended rather than the Menghini technique as less trauma is created.
dc.identifier.doi10.4274/vhd.galenos.2018.0030
dc.identifier.eissn2147-2939
dc.identifier.endpage5
dc.identifier.issn1307-9441
dc.identifier.issue1
dc.identifier.startpage1
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/16510
dc.identifier.volume25
dc.identifier.wosWOS:000466134600001
dc.language.isoen
dc.publisherGALENOS YAYINCILIK
dc.relation.ispartofVIRAL HEPATIT DERGISI-VIRAL HEPATITIS JOURNAL
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectChronic hepatitis B
dc.subjectliver
dc.subjectbiopsy
dc.subjecttechnique
dc.subjectneedle
dc.subjectCHRONIC VIRAL-HEPATITIS
dc.subjectCOMPLICATIONS
dc.subjectFIBROSIS
dc.subjectMedicine, General & Internal
dc.subjectGeneral & Internal Medicine
dc.titleA Comparison of Needle Types and Biopsy Techniques Used in Liver Biopsies of Chronic Hepatitis B Patients
dc.typeArticle
dspace.entity.typePublication
rdl.citation.trdizin0
rdl.citation.wos0
rdl.departmentERZİNCAN BİNALİ YILDIRIM ÜNİVERSİTESİ
rdl.oa.statusgold
rdl.source.indexWOS
rdl.source.indexTRDIZIN
rdl.wos.indexEmerging Sources Citation Index (ESCI)