Efficient fabrication of a benzydamine-selective PVC-membrane potentiometric sensor with broad dynamic range and ultra-low detection limit

ArticleAçık Erişim

Özet

A potentiometric poly(vinyl chloride) (PVC) membrane benzydamine (BZD)-selective sensor based on potassium tetrakis(4-chlorophenyl)borate (KTpClPB) as an electroactive material was fabricated with a broad linear range and ultra-low detection limit in a straightforward, cost-effective, and efficient manner. As an outcome of the membrane optimization research, it was found that the membrane composition that exhibited the best potentiometric performance metrics among the studied membrane compositions was 32.0% (w/w) PVC, 67.0% (w/w) o-NPOE (o-nitrophenyloctyl ether), and 1.0% (w/w) KTpClPB. The sensor displayed a linear response to BZD within the concentration range of 1.0 × 10−8 to 1.0 × 10−2 mol L-1, achieving a detection limit of 5.0 × 10− 9 mol L-1 and a sensitivity of 56.6 mV decade−1. The electrodes possessed a rapid response time of about 10 s. The sensor’s analytical capability was demonstrated by accurately quantifying the benzydamine content in multiple pharmaceuticals with benzydamine as the active component, yielding high recovery values. © The Author(s), under exclusive licence to the Institute of Chemistry, Slovak Academy of Sciences 2026.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/10588Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1007/s11696-025-04632-1Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorKircaer, Ozan
dc.contributor.authorKanberoglu, Gulsah Saydan
dc.contributor.authorColdur, Fatih
dc.date.accessioned2026-10-18T20:25:46.810501936Z
dc.date.available2026-10-18T20:25:46.810501936Z
dc.date.issued2026
dc.description.abstractA potentiometric poly(vinyl chloride) (PVC) membrane benzydamine (BZD)-selective sensor based on potassium tetrakis(4-chlorophenyl)borate (KTpClPB) as an electroactive material was fabricated with a broad linear range and ultra-low detection limit in a straightforward, cost-effective, and efficient manner. As an outcome of the membrane optimization research, it was found that the membrane composition that exhibited the best potentiometric performance metrics among the studied membrane compositions was 32.0% (w/w) PVC, 67.0% (w/w) o-NPOE (o-nitrophenyloctyl ether), and 1.0% (w/w) KTpClPB. The sensor displayed a linear response to BZD within the concentration range of 1.0 × 10−8 to 1.0 × 10−2 mol L-1, achieving a detection limit of 5.0 × 10− 9 mol L-1 and a sensitivity of 56.6 mV decade−1. The electrodes possessed a rapid response time of about 10 s. The sensor’s analytical capability was demonstrated by accurately quantifying the benzydamine content in multiple pharmaceuticals with benzydamine as the active component, yielding high recovery values. © The Author(s), under exclusive licence to the Institute of Chemistry, Slovak Academy of Sciences 2026.
dc.description.sponsorshipVan Yuzunc\u0131 Yil University Research Foundation, FYL-2024-11038, Gulsah Saydan Kanberoglu.
dc.identifier.doi10.1007/s11696-025-04632-1
dc.identifier.eissn2585-7290
dc.identifier.endpage3559
dc.identifier.issn0366-6352
dc.identifier.issue4
dc.identifier.scopus2-s2.0-105028271625
dc.identifier.startpage3551
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/10588
dc.identifier.volume80
dc.identifier.wosWOS:001667258200001
dc.language.isoen
dc.publisherSpringer Science and Business Media Deutschland GmbH
dc.relation.ispartofChemical Papers
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectBenzydamine HCl determination
dc.subjectIon-selective electrode
dc.subjectPharmaceutical analysis
dc.subjectPolymer membrane
dc.subjectPotentiometric sensor
dc.titleEfficient fabrication of a benzydamine-selective PVC-membrane potentiometric sensor with broad dynamic range and ultra-low detection limit
dc.typeArticle
dspace.entity.typePublication
rdl.citation.scopus0
rdl.citation.wos0
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)