A NOVEL TRAINING ALTERNATIVE IN ORTHOGNATHIC MANDIBULAR OSTEOTOMY: AIR DRIED CLAY MODEL; [ORTOGNATİK MANDİBULA OSTEOTOMİSİNDE YENİ BİR EǦİTİM SEÇENEǦİ: HAVA KURUTMALI KİL MODELİ]

ArticleAçık Erişim

Özet

Objective: Patient safety and low complication rates are indispensable in surgical training and models are among the main educational tools. The aim of this study is to assess the efficiency of a novel model for orthognathic mandibular osteotomy. Material and Methods: A template and seventeen partial mandibular models (MM-17) were manufactured with air dried clay. The dimensions of the models were feasible for sagittal split ramus osteotomy (SSRO). Model surgery was performed by surgeons with a minimum of three years' experience in orthognathic surgery. Each surgeon operated four separate models and the following data were recorded: corticotomy and SSRO completion time, MM-17 fracture type, similarity value of MM-17 with native mandible, representation value of MM-17, and the training compatibility value of MM-17. Results: The cost was 0.6 American Dollars. The mean corticotomy time was 126.75 seconds (110-150). Mean cortical resistance similarity value was 8.75 (8-10). The mean SSRO time was 288 seconds (205-401). Sixty percent of the fractures were seen in the outer cortex. The mean medullary resistance similarity value was 5 (4-6) and mean mandibular representation value was 5.25 (4-7). The training compatibility value was 8.25 (7-10). Conclusion: Air dried clay demonstrated mechanical similarities with bone cortex and it was used for mandibular modelling for the first time. MM-17 cost less than other devices. Corticotomy and SSRO completion times were short due to the lack of dissection and bleeding. Despite its drawbacks in SSRO, MM- 17 is a versatile and low cost alternative in orthognathic mandibular corticotomy training. High power drill utilization skills may be gained with MM-17 before clinical practice. © 2020 Taru Publications. All rights reserved.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/13022Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.26650/iuitfd.2021.836789Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorKozanoǧlu, Erol
dc.contributor.authorAkalin, Bora Edim
dc.contributor.authorBerköz, Hayri Ömer
dc.contributor.authorKaraali˙, Soner
dc.contributor.authorMammadova, Nermin
dc.contributor.authorAk, Erman
dc.contributor.authorYücel, Ahmet Faruk
dc.contributor.authorEmekli˙, Ufuk
dc.date.accessioned2026-10-18T20:27:52.092830418Z
dc.date.available2026-10-18T20:27:52.092830418Z
dc.date.issued2021
dc.description.abstractObjective: Patient safety and low complication rates are indispensable in surgical training and models are among the main educational tools. The aim of this study is to assess the efficiency of a novel model for orthognathic mandibular osteotomy. Material and Methods: A template and seventeen partial mandibular models (MM-17) were manufactured with air dried clay. The dimensions of the models were feasible for sagittal split ramus osteotomy (SSRO). Model surgery was performed by surgeons with a minimum of three years' experience in orthognathic surgery. Each surgeon operated four separate models and the following data were recorded: corticotomy and SSRO completion time, MM-17 fracture type, similarity value of MM-17 with native mandible, representation value of MM-17, and the training compatibility value of MM-17. Results: The cost was 0.6 American Dollars. The mean corticotomy time was 126.75 seconds (110-150). Mean cortical resistance similarity value was 8.75 (8-10). The mean SSRO time was 288 seconds (205-401). Sixty percent of the fractures were seen in the outer cortex. The mean medullary resistance similarity value was 5 (4-6) and mean mandibular representation value was 5.25 (4-7). The training compatibility value was 8.25 (7-10). Conclusion: Air dried clay demonstrated mechanical similarities with bone cortex and it was used for mandibular modelling for the first time. MM-17 cost less than other devices. Corticotomy and SSRO completion times were short due to the lack of dissection and bleeding. Despite its drawbacks in SSRO, MM- 17 is a versatile and low cost alternative in orthognathic mandibular corticotomy training. High power drill utilization skills may be gained with MM-17 before clinical practice. © 2020 Taru Publications. All rights reserved.
dc.identifier.doi10.26650/iuitfd.2021.836789
dc.identifier.eissn1305-6441
dc.identifier.endpage487
dc.identifier.issn1305-6433
dc.identifier.issue4
dc.identifier.scopus2-s2.0-85130417506
dc.identifier.startpage482
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/13022
dc.identifier.volume84
dc.identifier.wosWOS:000704257000009
dc.language.isoen
dc.publisherIstanbul University Press
dc.relation.ispartofIstanbul Tip Fakultesi Dergisi
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectAir-dried clay
dc.subjectmandible
dc.subjectmodel surgery
dc.subjectorthognathic surgery
dc.subjecttraining
dc.titleA NOVEL TRAINING ALTERNATIVE IN ORTHOGNATHIC MANDIBULAR OSTEOTOMY: AIR DRIED CLAY MODEL; [ORTOGNATİK MANDİBULA OSTEOTOMİSİNDE YENİ BİR EǦİTİM SEÇENEǦİ: HAVA KURUTMALI KİL MODELİ]
dc.typeArticle
dspace.entity.typePublication
rdl.citation.scopus0
rdl.citation.trdizin0
rdl.citation.wos0
rdl.departmentİSTANBUL ÜNİVERSİTESİ
rdl.departmentERZİNCAN BİNALİ YILDIRIM ÜNİVERSİTESİ
rdl.departmentT.C. SAĞLIK BAKANLIĞI
rdl.departmentSAĞLIK BİLİMLERİ ÜNİVERSİTESİ
rdl.oa.statusgold
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.source.indexTRDIZIN
rdl.wos.indexEmerging Sources Citation Index (ESCI)