A NOVEL TRAINING ALTERNATIVE IN ORTHOGNATHIC MANDIBULAR OSTEOTOMY: AIR DRIED CLAY MODEL; [ORTOGNATİK MANDİBULA OSTEOTOMİSİNDE YENİ BİR EǦİTİM SEÇENEǦİ: HAVA KURUTMALI KİL MODELİ]
Özet
Objective: Patient safety and low complication rates are indispensable in surgical training and models are among the main educational tools. The aim of this study is to assess the efficiency of a novel model for orthognathic mandibular osteotomy. Material and Methods: A template and seventeen partial mandibular models (MM-17) were manufactured with air dried clay. The dimensions of the models were feasible for sagittal split ramus osteotomy (SSRO). Model surgery was performed by surgeons with a minimum of three years' experience in orthognathic surgery. Each surgeon operated four separate models and the following data were recorded: corticotomy and SSRO completion time, MM-17 fracture type, similarity value of MM-17 with native mandible, representation value of MM-17, and the training compatibility value of MM-17. Results: The cost was 0.6 American Dollars. The mean corticotomy time was 126.75 seconds (110-150). Mean cortical resistance similarity value was 8.75 (8-10). The mean SSRO time was 288 seconds (205-401). Sixty percent of the fractures were seen in the outer cortex. The mean medullary resistance similarity value was 5 (4-6) and mean mandibular representation value was 5.25 (4-7). The training compatibility value was 8.25 (7-10). Conclusion: Air dried clay demonstrated mechanical similarities with bone cortex and it was used for mandibular modelling for the first time. MM-17 cost less than other devices. Corticotomy and SSRO completion times were short due to the lack of dissection and bleeding. Despite its drawbacks in SSRO, MM- 17 is a versatile and low cost alternative in orthognathic mandibular corticotomy training. High power drill utilization skills may be gained with MM-17 before clinical practice. © 2020 Taru Publications. All rights reserved.
Anahtar Kelimeler
Tam Kayıt
| Alan | Değer | Dil |
|---|---|---|
| dc.contributor.author | Kozanoǧlu, Erol | |
| dc.contributor.author | Akalin, Bora Edim | |
| dc.contributor.author | Berköz, Hayri Ömer | |
| dc.contributor.author | Karaali˙, Soner | |
| dc.contributor.author | Mammadova, Nermin | |
| dc.contributor.author | Ak, Erman | |
| dc.contributor.author | Yücel, Ahmet Faruk | |
| dc.contributor.author | Emekli˙, Ufuk | |
| dc.date.accessioned | 2026-10-18T20:27:52.092830418Z | |
| dc.date.available | 2026-10-18T20:27:52.092830418Z | |
| dc.date.issued | 2021 | |
| dc.description.abstract | Objective: Patient safety and low complication rates are indispensable in surgical training and models are among the main educational tools. The aim of this study is to assess the efficiency of a novel model for orthognathic mandibular osteotomy. Material and Methods: A template and seventeen partial mandibular models (MM-17) were manufactured with air dried clay. The dimensions of the models were feasible for sagittal split ramus osteotomy (SSRO). Model surgery was performed by surgeons with a minimum of three years' experience in orthognathic surgery. Each surgeon operated four separate models and the following data were recorded: corticotomy and SSRO completion time, MM-17 fracture type, similarity value of MM-17 with native mandible, representation value of MM-17, and the training compatibility value of MM-17. Results: The cost was 0.6 American Dollars. The mean corticotomy time was 126.75 seconds (110-150). Mean cortical resistance similarity value was 8.75 (8-10). The mean SSRO time was 288 seconds (205-401). Sixty percent of the fractures were seen in the outer cortex. The mean medullary resistance similarity value was 5 (4-6) and mean mandibular representation value was 5.25 (4-7). The training compatibility value was 8.25 (7-10). Conclusion: Air dried clay demonstrated mechanical similarities with bone cortex and it was used for mandibular modelling for the first time. MM-17 cost less than other devices. Corticotomy and SSRO completion times were short due to the lack of dissection and bleeding. Despite its drawbacks in SSRO, MM- 17 is a versatile and low cost alternative in orthognathic mandibular corticotomy training. High power drill utilization skills may be gained with MM-17 before clinical practice. © 2020 Taru Publications. All rights reserved. | |
| dc.identifier.doi | 10.26650/iuitfd.2021.836789 | |
| dc.identifier.eissn | 1305-6441 | |
| dc.identifier.endpage | 487 | |
| dc.identifier.issn | 1305-6433 | |
| dc.identifier.issue | 4 | |
| dc.identifier.scopus | 2-s2.0-85130417506 | |
| dc.identifier.startpage | 482 | |
| dc.identifier.uri | https://rdlopen.rawdatalibrary.net/r/ebyu/13022 | |
| dc.identifier.volume | 84 | |
| dc.identifier.wos | WOS:000704257000009 | |
| dc.language.iso | en | |
| dc.publisher | Istanbul University Press | |
| dc.relation.ispartof | Istanbul Tip Fakultesi Dergisi | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.subject | Air-dried clay | |
| dc.subject | mandible | |
| dc.subject | model surgery | |
| dc.subject | orthognathic surgery | |
| dc.subject | training | |
| dc.title | A NOVEL TRAINING ALTERNATIVE IN ORTHOGNATHIC MANDIBULAR OSTEOTOMY: AIR DRIED CLAY MODEL; [ORTOGNATİK MANDİBULA OSTEOTOMİSİNDE YENİ BİR EǦİTİM SEÇENEǦİ: HAVA KURUTMALI KİL MODELİ] | |
| dc.type | Article | |
| dspace.entity.type | Publication | |
| rdl.citation.scopus | 0 | |
| rdl.citation.trdizin | 0 | |
| rdl.citation.wos | 0 | |
| rdl.department | İSTANBUL ÜNİVERSİTESİ | |
| rdl.department | ERZİNCAN BİNALİ YILDIRIM ÜNİVERSİTESİ | |
| rdl.department | T.C. SAĞLIK BAKANLIĞI | |
| rdl.department | SAĞLIK BİLİMLERİ ÜNİVERSİTESİ | |
| rdl.oa.status | gold | |
| rdl.source.index | SCOPUS | |
| rdl.source.index | WOS | |
| rdl.source.index | TRDIZIN | |
| rdl.wos.index | Emerging Sources Citation Index (ESCI) |
