Effect of Prone and Supine Positioning on Computed Tomography Urography Examination
Özet
Objectives: The aim of this study is to evaluate the effects of performing computed tomography (CT) urogram in the prone position in terms of diagnosis. Methods: CT urograms of 208 patients imaged randomly in the prone and supine positions were included in this study. A total of 199 patients and 370 collecting systems were examined in total. Axial raw data and reconstructed coronal thin and thick MIP images with a slice thickness of 5 mm were evaluated by 2 independent radiologists blinded to the initial diagnosis. Renal collecting system, ureters, and bladder were included in radiological evaluation. Anatomically, the renal collecting system was separated into 7 regions. Filling and dilatation of collecting systems were evaluated via images at urogram phase by scoring. Results: Filling in lower pole infundibulum (p = 0.006), distal ureter (p = 0.006); and highly dilated lower pole calyx (p = 0.020), pelvis (p = 0.006), and bladder (p < 0.001) were determined to be better in images in the prone position compared to the supine position. There were no statistical differences in other regions. Conclusion: Better contrast material filling is achieved in dilated or non-dilated lower pole collecting system, dilated renal pelvis, non-dilated distal ureter of kidney, and in the bladder only by imaging the urogram phase in the prone position compared to the supine position. Additionally, presence of dilatation is a factor that could adversely affect filling. Studies in the future may investigate the contribution of prone positioning to CT urogram with larger series comparing it with other methods and modalities. © 2018 2018 S. Karger AG, Basel.
Anahtar Kelimeler
Tam Kayıt
| Alan | Değer | Dil |
|---|---|---|
| dc.contributor.author | Karavaş, Erdal | |
| dc.contributor.author | Gürel, Safiye | |
| dc.contributor.author | Klyan, Aysu | |
| dc.contributor.author | Halicioǧlu, Slddlka | |
| dc.contributor.author | Daǧistan, Emine | |
| dc.date.accessioned | 2026-10-18T20:28:59.255721044Z | |
| dc.date.available | 2026-10-18T20:28:59.255721044Z | |
| dc.date.issued | 2018 | |
| dc.description.abstract | Objectives: The aim of this study is to evaluate the effects of performing computed tomography (CT) urogram in the prone position in terms of diagnosis. Methods: CT urograms of 208 patients imaged randomly in the prone and supine positions were included in this study. A total of 199 patients and 370 collecting systems were examined in total. Axial raw data and reconstructed coronal thin and thick MIP images with a slice thickness of 5 mm were evaluated by 2 independent radiologists blinded to the initial diagnosis. Renal collecting system, ureters, and bladder were included in radiological evaluation. Anatomically, the renal collecting system was separated into 7 regions. Filling and dilatation of collecting systems were evaluated via images at urogram phase by scoring. Results: Filling in lower pole infundibulum (p = 0.006), distal ureter (p = 0.006); and highly dilated lower pole calyx (p = 0.020), pelvis (p = 0.006), and bladder (p < 0.001) were determined to be better in images in the prone position compared to the supine position. There were no statistical differences in other regions. Conclusion: Better contrast material filling is achieved in dilated or non-dilated lower pole collecting system, dilated renal pelvis, non-dilated distal ureter of kidney, and in the bladder only by imaging the urogram phase in the prone position compared to the supine position. Additionally, presence of dilatation is a factor that could adversely affect filling. Studies in the future may investigate the contribution of prone positioning to CT urogram with larger series comparing it with other methods and modalities. © 2018 2018 S. Karger AG, Basel. | |
| dc.identifier.doi | 10.1159/000490735 | |
| dc.identifier.eissn | 1423-0399 | |
| dc.identifier.endpage | 174 | |
| dc.identifier.issn | 0042-1138 | |
| dc.identifier.issue | 2 | |
| dc.identifier.pmid | 29982255 | |
| dc.identifier.scopus | 2-s2.0-85049892300 | |
| dc.identifier.startpage | 167 | |
| dc.identifier.uri | https://rdlopen.rawdatalibrary.net/r/ebyu/14198 | |
| dc.identifier.volume | 101 | |
| dc.identifier.wos | WOS:000442614900007 | |
| dc.language.iso | en | |
| dc.publisher | S. Karger AG | |
| dc.relation.ispartof | Urologia Internationalis | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.subject | Computed tomography | |
| dc.subject | MSCT | |
| dc.subject | Prone | |
| dc.subject | Supine | |
| dc.subject | Urography | |
| dc.subject | Adolescent | |
| dc.subject | Adult | |
| dc.subject | Aged | |
| dc.subject | Aged, 80 and over | |
| dc.subject | Child | |
| dc.subject | Child, Preschool | |
| dc.subject | Contrast Media | |
| dc.subject | Humans | |
| dc.subject | Kidney | |
| dc.subject | Middle Aged | |
| dc.subject | Patient Positioning | |
| dc.subject | Predictive Value of Tests | |
| dc.subject | Prone Position | |
| dc.subject | Supine Position | |
| dc.subject | Tomography, X-Ray Computed | |
| dc.subject | Ureter | |
| dc.subject | Urinary Bladder | |
| dc.subject | Urinary Tract | |
| dc.subject | Urologic Diseases | |
| dc.subject | Young Adult | |
| dc.subject | contrast medium | |
| dc.subject | Article | |
| dc.subject | computer assisted tomography | |
| dc.subject | controlled study | |
| dc.subject | cystography | |
| dc.title | Effect of Prone and Supine Positioning on Computed Tomography Urography Examination | |
| dc.type | Article | |
| dspace.entity.type | Publication | |
| rdl.citation.scopus | 4 | |
| rdl.citation.wos | 2 | |
| rdl.department | Department of Radiology, Faculty of Medicine, Erzincan University, Erzincan, Turkey. | |
| rdl.source.index | SCOPUS | |
| rdl.source.index | WOS | |
| rdl.source.index | PUBMED | |
| rdl.wos.index | Science Citation Index Expanded (SCI-EXPANDED) | |
| rdl.wos.index | Conference Proceedings Citation Index - Science (CPCI-S) |
