Audiometric threshold shifts after total knee arthroplasty by using gentamicin-loaded bone cement
Özet
Background/aim: The aim of this study was to investigate postoperative audiometric threshold shifts in patients who underwent primary total knee arthroplasty (TKA) using gentamicin-loaded bone cement (GLBC) in comparison with the ones who underwent TKA without GLBC. Materials and methods: Forty patients (gentamicin group) who underwent primary TKA using GLBC and 29 patients (control group) who underwent primary TKA using standard bone cement were included in this prospective case-control study. Baseline pure-tone audiometric evaluation was performed preoperatively and repeated at the postoperative third day for all patients. Control audiometric evaluation was performed weekly for patients who were diagnosed with ototoxicity according to audiometric threshold shifts. Results: Ototoxicity was diagnosed in 8 of 40 patients (20%) in the gentamicin group according to postoperative audiometric threshold shifts, whereas no ototoxicity was observed in the control group. Patients who were diagnosed with ototoxicity had no permanent audiometric threshold shifts in follow-up audiometric evaluation and these patients had no clinical complaints of difference in hearing. Conclusion: According to our results, audiometric threshold shifts can be detected in patients who undergo primary TKA usingentamicin loaded bone cement. However, no permanent shifts were observed during close follow-up. © TÜBİTAK.
Anahtar Kelimeler
Tam Kayıt
| Alan | Değer | Dil |
|---|---|---|
| dc.contributor.author | Çöbden, Adem | |
| dc.contributor.author | Çamurcu, Yalkın | |
| dc.contributor.author | Çöbden, Serap Bulut | |
| dc.contributor.author | Sofu, Hakan | |
| dc.contributor.author | Üçpunar, Hanifi | |
| dc.contributor.author | Sevencan, Ahmet | |
| dc.contributor.author | Demirel, Hüseyin | |
| dc.date.accessioned | 2026-10-18T20:28:54.838389115Z | |
| dc.date.available | 2026-10-18T20:28:54.838389115Z | |
| dc.date.issued | 2019 | |
| dc.description.abstract | Background/aim: The aim of this study was to investigate postoperative audiometric threshold shifts in patients who underwent primary total knee arthroplasty (TKA) using gentamicin-loaded bone cement (GLBC) in comparison with the ones who underwent TKA without GLBC. Materials and methods: Forty patients (gentamicin group) who underwent primary TKA using GLBC and 29 patients (control group) who underwent primary TKA using standard bone cement were included in this prospective case-control study. Baseline pure-tone audiometric evaluation was performed preoperatively and repeated at the postoperative third day for all patients. Control audiometric evaluation was performed weekly for patients who were diagnosed with ototoxicity according to audiometric threshold shifts. Results: Ototoxicity was diagnosed in 8 of 40 patients (20%) in the gentamicin group according to postoperative audiometric threshold shifts, whereas no ototoxicity was observed in the control group. Patients who were diagnosed with ototoxicity had no permanent audiometric threshold shifts in follow-up audiometric evaluation and these patients had no clinical complaints of difference in hearing. Conclusion: According to our results, audiometric threshold shifts can be detected in patients who undergo primary TKA usingentamicin loaded bone cement. However, no permanent shifts were observed during close follow-up. © TÜBİTAK. | |
| dc.identifier.doi | 10.3906/sag-1710-135 | |
| dc.identifier.eissn | 1303-6165 | |
| dc.identifier.endpage | 518 | |
| dc.identifier.issn | 1300-0144 | |
| dc.identifier.issue | 2 | |
| dc.identifier.pmid | 30893980 | |
| dc.identifier.scopus | 2-s2.0-85065050251 | |
| dc.identifier.startpage | 514 | |
| dc.identifier.uri | https://rdlopen.rawdatalibrary.net/r/ebyu/14134 | |
| dc.identifier.volume | 49 | |
| dc.identifier.wos | WOS:000465264700010 | |
| dc.language.iso | en | |
| dc.publisher | Turkiye Klinikleri | |
| dc.relation.ispartof | Turkish Journal of Medical Sciences | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.subject | Antibiotic-loaded bone cement | |
| dc.subject | Audiometry | |
| dc.subject | Gentamicin | |
| dc.subject | Ototoxicity | |
| dc.subject | Total knee arthroplasty | |
| dc.subject | Aged | |
| dc.subject | Aged, 80 and over | |
| dc.subject | Anti-Bacterial Agents | |
| dc.subject | Arthroplasty, Replacement, Knee | |
| dc.subject | Audiometry, Pure-Tone | |
| dc.subject | Bone Cements | |
| dc.subject | Case-Control Studies | |
| dc.subject | Female | |
| dc.subject | Gentamicins | |
| dc.subject | Hearing | |
| dc.subject | Humans | |
| dc.subject | Male | |
| dc.subject | Middle Aged | |
| dc.subject | Prospective Studies | |
| dc.subject | Prosthesis-Related Infections | |
| dc.subject | Treatment Outcome | |
| dc.subject | cephalosporin | |
| dc.subject | gentamicin bone cement | |
| dc.subject | low molecular weight heparin | |
| dc.subject | antiinfective agent | |
| dc.subject | bone cement | |
| dc.subject | Article | |
| dc.subject | auditory threshold shift | |
| dc.subject | case control study | |
| dc.subject | clinical article | |
| dc.title | Audiometric threshold shifts after total knee arthroplasty by using gentamicin-loaded bone cement | |
| dc.type | Article | |
| dspace.entity.type | Publication | |
| rdl.citation.scopus | 6 | |
| rdl.citation.trdizin | 0 | |
| rdl.citation.wos | 5 | |
| rdl.department | T.C. SAĞLIK BAKANLIĞI | |
| rdl.department | ERZİNCAN BİNALİ YILDIRIM ÜNİVERSİTESİ | |
| rdl.oa.status | gold | |
| rdl.source.index | SCOPUS | |
| rdl.source.index | WOS | |
| rdl.source.index | TRDIZIN | |
| rdl.wos.index | Science Citation Index Expanded (SCI-EXPANDED) |