Effect of Prone and Supine Positioning on Computed Tomography Urography Examination

ArticleAçık Erişim

Özet

Objectives: The aim of this study is to evaluate the effects of performing computed tomography (CT) urogram in the prone position in terms of diagnosis. Methods: CT urograms of 208 patients imaged randomly in the prone and supine positions were included in this study. A total of 199 patients and 370 collecting systems were examined in total. Axial raw data and reconstructed coronal thin and thick MIP images with a slice thickness of 5 mm were evaluated by 2 independent radiologists blinded to the initial diagnosis. Renal collecting system, ureters, and bladder were included in radiological evaluation. Anatomically, the renal collecting system was separated into 7 regions. Filling and dilatation of collecting systems were evaluated via images at urogram phase by scoring. Results: Filling in lower pole infundibulum (p = 0.006), distal ureter (p = 0.006); and highly dilated lower pole calyx (p = 0.020), pelvis (p = 0.006), and bladder (p < 0.001) were determined to be better in images in the prone position compared to the supine position. There were no statistical differences in other regions. Conclusion: Better contrast material filling is achieved in dilated or non-dilated lower pole collecting system, dilated renal pelvis, non-dilated distal ureter of kidney, and in the bladder only by imaging the urogram phase in the prone position compared to the supine position. Additionally, presence of dilatation is a factor that could adversely affect filling. Studies in the future may investigate the contribution of prone positioning to CT urogram with larger series comparing it with other methods and modalities. © 2018 2018 S. Karger AG, Basel.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/ebyu/14198Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1159/000490735Yayıncı resmi DOI adresi
Tam Kayıt
AlanDeğerDil
dc.contributor.authorKaravaş, Erdal
dc.contributor.authorGürel, Safiye
dc.contributor.authorKlyan, Aysu
dc.contributor.authorHalicioǧlu, Slddlka
dc.contributor.authorDaǧistan, Emine
dc.date.accessioned2026-10-18T20:28:59.255721044Z
dc.date.available2026-10-18T20:28:59.255721044Z
dc.date.issued2018
dc.description.abstractObjectives: The aim of this study is to evaluate the effects of performing computed tomography (CT) urogram in the prone position in terms of diagnosis. Methods: CT urograms of 208 patients imaged randomly in the prone and supine positions were included in this study. A total of 199 patients and 370 collecting systems were examined in total. Axial raw data and reconstructed coronal thin and thick MIP images with a slice thickness of 5 mm were evaluated by 2 independent radiologists blinded to the initial diagnosis. Renal collecting system, ureters, and bladder were included in radiological evaluation. Anatomically, the renal collecting system was separated into 7 regions. Filling and dilatation of collecting systems were evaluated via images at urogram phase by scoring. Results: Filling in lower pole infundibulum (p = 0.006), distal ureter (p = 0.006); and highly dilated lower pole calyx (p = 0.020), pelvis (p = 0.006), and bladder (p < 0.001) were determined to be better in images in the prone position compared to the supine position. There were no statistical differences in other regions. Conclusion: Better contrast material filling is achieved in dilated or non-dilated lower pole collecting system, dilated renal pelvis, non-dilated distal ureter of kidney, and in the bladder only by imaging the urogram phase in the prone position compared to the supine position. Additionally, presence of dilatation is a factor that could adversely affect filling. Studies in the future may investigate the contribution of prone positioning to CT urogram with larger series comparing it with other methods and modalities. © 2018 2018 S. Karger AG, Basel.
dc.identifier.doi10.1159/000490735
dc.identifier.eissn1423-0399
dc.identifier.endpage174
dc.identifier.issn0042-1138
dc.identifier.issue2
dc.identifier.pmid29982255
dc.identifier.scopus2-s2.0-85049892300
dc.identifier.startpage167
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/ebyu/14198
dc.identifier.volume101
dc.identifier.wosWOS:000442614900007
dc.language.isoen
dc.publisherS. Karger AG
dc.relation.ispartofUrologia Internationalis
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectComputed tomography
dc.subjectMSCT
dc.subjectProne
dc.subjectSupine
dc.subjectUrography
dc.subjectAdolescent
dc.subjectAdult
dc.subjectAged
dc.subjectAged, 80 and over
dc.subjectChild
dc.subjectChild, Preschool
dc.subjectContrast Media
dc.subjectHumans
dc.subjectKidney
dc.subjectMiddle Aged
dc.subjectPatient Positioning
dc.subjectPredictive Value of Tests
dc.subjectProne Position
dc.subjectSupine Position
dc.subjectTomography, X-Ray Computed
dc.subjectUreter
dc.subjectUrinary Bladder
dc.subjectUrinary Tract
dc.subjectUrologic Diseases
dc.subjectYoung Adult
dc.subjectcontrast medium
dc.subjectArticle
dc.subjectcomputer assisted tomography
dc.subjectcontrolled study
dc.subjectcystography
dc.titleEffect of Prone and Supine Positioning on Computed Tomography Urography Examination
dc.typeArticle
dspace.entity.typePublication
rdl.citation.scopus4
rdl.citation.wos2
rdl.departmentDepartment of Radiology, Faculty of Medicine, Erzincan University, Erzincan, Turkey.
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.source.indexPUBMED
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)
rdl.wos.indexConference Proceedings Citation Index - Science (CPCI-S)